Samsung SADT-100PM ユーザーズマニュアル

ページ / 15
2
GB
1
Wall Mount
Adaptor
Back Plate
Pole Mount
Adaptor
Stainless Steel
Mounting Strap
Cable Grand
Summary
The Pole Mounted Adaptor (SADT-100PM) is used for the
installation of the Wall Mounted Adaptor on cylindrical poles with a
diameter greater than 80mm.
Precautions Before Installation
Make sure that the proposed location can support the combined weights of the Pole
Mounted Adaptor, Wall Mounted Adaptor, Outdoor Housing and Smartdome
Camera (about 10 kg).
When installing the product outdoors, use interlocking devices made of stainless
steel.
This goods should only be installed by a qualified technician using approved materials
and wiring practices in accordance with national, state, and local electrical code.
Installation
Select the pole and the height for installation.
Securely fasten the Pole Mounted Adaptor to the pole with the
stainless steel mounting strap.
Pull the cables out through the Pole Mounted Adaptor and the
Wall Mounted Adaptor.
1. Assemble the PG-13.5 cable gland on the Back Plate.
2. Pull the cables through the cable gland to the Wall Mounted Adaptor.
3. Assemble the Back Plate with six screws (FH M3 x L8).
1
2
3
SADT-100PM(GB)  
2007.4.23 4:12 PM  
페이지1  
 001 AGFA Avantra 25E-TAIPAN