Control codes
Get control
Header
command
ID
DATA Length
CheckSum
0xAA
command type
0
Set control
Header
command
ID
DATA
Length
DATA
CheckSum
0xAA
command
type
1
Value
commanding words
No.
command type
command
Value range
1
Power control
0x11
0~1
2
Volume control
0x12
0~100
3
Input source control
0x14
-
4
Screen Mode control
0x18
-
5
Screen Size control
0x19
0~255
6
PIP on/off control
0x3C
0~1
7
Auto adjustment control
0x3D
0
8
Video wall Mode control
0x5C
0~1
9
Safety Lock
0x5D
0~1
- ID should show hexadecimal value of assigned ID, but ID 0 should be 0xFF.
- Every communication will be made in hexadecimals and Checksum is the sum of all remainings.
If it exceeds two digits,for example, it is 11+FF+01+01=112, discard the number in the first digit
like below.
example)PowerOn&ID=0