Samsung AR09MVFHJWKXME インストールガイド

ページ / 2
Installation manual 
AR✴✴MVFH✴✴
Safety Information on 
Installation
Carefully follow the precautions listed below because 
they are essential to guarantee the safety of both the 
air conditioner and the workers.
• Always disconnect the air conditioner from the power 
supply before servicing it or accessing its internal 
components. 
• Verify that installation and testing operations are 
performed by qualified personnel. 
• Verify that the air conditioner is not installed in an 
easily accessible area. 
General information
• Carefully read the content of this manual before 
installing the air conditioner and store the manual in 
a safe place in order to be able to use it as reference 
after installation. 
• For maximum safety, installers should always 
carefully read the following warnings. 
• Store the operation and installation manual in a safe 
location and remember to hand it over to the new 
owner if the air conditioner is sold or transferred. 
• This manual explains how to install an indoor unit 
with a split system with two SAMSUNG units. The use 
of other types of units with different control systems 
may damage the units and invalidate the warranty. 
The manufacturer shall not be responsible for 
damages arising from the use of non compliant units. 
• This product has been determined to be in 
compliance with the Low Voltage Directive (2006/95/
EC) and the Electromagnetic Compatibility Directive 
(2004/108/EC) of the European Union.
• The manufacturer shall not be responsible for 
damage originating from unauthorised changes or 
the improper connection of electric and requirements 
set forth in the “Operating limits” table, included 
in the manual, shall immediately invalidate the 
warranty.  
 
• The air conditioner should be used only for the 
applications for which it has been designed: the 
indoor unit is not suitable to be installed in areas 
used for laundry. 
• Do not use the units if damaged. If problems occur, 
switch the unit off and disconnect it from the power 
supply.
• In order to help prevent electric shocks, fires or 
injuries, always stop the unit, disable the protection 
switch and contact SAMSUNG’s technical support if 
the unit produces smoke, if the power cable is hot or 
damaged or if the unit is very noisy. 
• Always remember to inspect the unit, electric 
connections, refrigerant tubes and protections 
regularly. These operations should be performed by 
qualified personnel only. 
• The unit contains moving parts, which should always 
be kept out of the reach of children. 
• Do not attempt to repair, move, alter or reinstall the 
unit. If performed by unauthorised personnel, these 
operations may cause electric shocks or fires. 
• Do not place containers with liquids or other objects 
on the unit. 
• All the materials used for the manufacture and 
packaging of the air conditioner are recyclable. 
• The packing material and exhaust batteries of the 
remote control (optional) must be disposed of in 
accordance with current laws. 
• The air conditioner contains a refrigerant that has 
to be disposed of as special waste. At the end of its 
life cycle, the air conditioner must be disposed of in 
authorised centres or returned to the retailer so that 
it can be disposed of correctly and safely.
Installation of the unit
• IMPORTANT: When installing the unit, always 
remember to connect first the refrigerant tubes, then 
the electrical lines. Always disassemble the electric 
lines before the refrigerant tubes. 
• Upon receipt, inspect the product to verify that 
it has not been damaged during transport. If the 
product appears damaged, DO NOT INSTALL it and 
immediately report the damage to the carrier or 
retailer (if the installer or the authorised technician 
has collected the material from the retailer.) 
• After completing the installation, always carry out a 
functional test and provide the instructions on how to 
operate the air conditioner to the user.
• Do not use the air conditioner in environments with 
hazardous substances or close to equipment that 
release free flames to avoid the occurrence of fires, 
explosions or injuries. 
• Our units must be installed in compliance with the 
spaces indicated in the installation manual to ensure 
either accessibility from both sides or ability to 
perform routine maintenance and repairs. The units’ 
components must be accessible and that can be 
disassembled in conditions of complete safety either 
for people or things. For this reason, where it is not 
observed as indicated into the Installation Manual, the 
cost necessary to reach and repair the unit (in safety, 
as required by current regulations in force) with slings, 
trucks, scaffolding or any other means of elevation 
won’t be considered in-warranty and will be charged 
to end user.
• When installing the outdoor unit at the seaside, make 
sure that it is not directly exposed to sea breeze. If 
you cannot find an adequate place free from direct 
sea breeze, construct a protection wall or a protective 
fence.
 
Install the outdoor unit in a place (such as near 
buildings etc.) where it can be protected from sea 
breeze. Failure to do so may cause a damage to the 
outdoor unit.
Sea
Sea breeze
Outdoor unit
Outdoor unit
Sea breeze
Sea
• If you cannot avoid installing the outdoor unit at the 
seaside, construct a protection wall around to block 
the sea breeze.
• Construct a protection wall with a solid material such 
as concrete to block the sea breeze. Make sure that 
the height and the width of the wall are 1.5 times 
larger than the size of the outdoor unit. Also, secure 
a space larger than 600 mm between the protection 
wall and the outdoor unit for exhausted air to ventilate.
Sea
Sea breeze
Outdoor unit
Protection wall
Outdoor unit
Protection wall
• Install the unit in a place where water can drain 
smoothly.
• If you have any difficulty finding installation location 
as prescribed above, contact your manufacturer for 
details.
• Be sure to clean the sea water and the dust on the 
heat exchanger of the outdoor unit and apply a 
corrosion inhibitor on it. (At least once in a year.)
Power supply line, fuse, or circuit 
breaker
• Always make sure that the power supply is compliant 
with current safety standards. Always install the air 
conditioner in compliance with current local safety 
standards. 
• Always verify that a suitable grounding connection is 
available. 
• Verify that the voltage and frequency of the power 
supply comply with the specifications and that the 
installed power is sufficient to ensure the operation of 
any other domestic appliance connected to the same 
electric lines. 
• Always verify that the cut-off and protection switches 
are suitably dimensioned. 
• Verify that the air conditioner is connected to the 
power supply in accordance with the instructions 
provided in the wiring diagram included in the manual. 
• Always verify that electric connections (cable entry, 
section of leads, protections…) are compliant with 
the electric specifications and with the instructions 
provided in the wiring scheme. Always verify that all 
connections comply with the standards applicable to 
the installation of air conditioners.
• Be sure not to perform power cable modification, 
extension wiring, and multiple wire connection.
 
It may cause electric shock or fire due to poor 
connection, poor insulation, or current limit 
override.
 
When extension wiring is required due to power line 
damage, refer to "Step 2.2 Optional: Extending the 
power cable" in the installation manual.
Preparation
Step 1.1  Choosing the installation 
location
Overview of installation location requirements
100 mm or more
Outdoor 
Unit
Indoor Unit
Cut insulation to have 
rainwater drained
Outer wall
Drain hose hole
You can select the direction of 
draining (left or right). 
Maximum pipe height: 15 m
Maximum pipe length: 30 m
125 mm or 
more
125 mm or 
more
The actual units may look different from the 
images depicted here.
Make a U-trap (A) on the pipe 
(which is connected to the indoor 
unit) at outer wall and cut the 
bottom part of the insulation 
(about 10 mm) to prevent 
rainwater from getting inside 
through the insulation. 
Make at least one round to reduce 
noise and vibration.
CAUTION
  CAUTION
• Comply with the length and height limits described in 
the figure above.
Minimum clearances for the outdoor unit
Wall
Minimum clearance in mm
300
600
Air flow direction
Side view
Top view
When installing 1 outdoor unit                              (6 cases)
(Unit: mm)
300
1500 
300
150
600
1500
2000 
500 
300 
300
 
1500
 (Unit : m)
Model
Pipe length
Pipe height
Minimum
Maximum
Maximum
✴✴
09/10/12/13✴✴
3
15
7
 ✴✴18/24✴✴
3
20
12
When installing more than 1 outdoor unit           (5 cases)
(Unit: mm)
1500
600
3000
200
3000
300
1500
600
600
1500
300
300
600
600
600
500 
300
500
300
  CAUTION
• If the outdoor unit is installed with any insufficient 
clearance, it may generate sound and affect the 
whole product.
• Be sure to install the outdoor unit in a level place 
where its vibration does not affect the whole product.
Step 1.2  Unpacking
Unpacking the indoor unit
1  Open the indoor unit package. 
2  Remove the left and right cushions. 
3  Pull out the unit from the package. 
Unpacking the outdoor unit
1  Remove the package. 
2  Remove the top cushion. 
3  Pull out the unit from the bottom cushion. 
Step 1.3  Checking and preparing 
accessories and tools
Accessories
Accessories in the indoor unit package
Installation plate (1)
✴✴
09/10/12/13✴✴
Installation plate (1)
✴✴
18/24✴✴
Remote control (1)
Remote control holder (1)
Remote control battery (2)
User Manual (1)
Installation Manual (1)
M4 x 12 tapping screw (2)
Optional accessories
Insulated assembly pipe,  
Ø 6.35 mm (1)
Insulated assembly pipe,  
Ø 9.52 mm (1) 
✴✴
09/10/12/13✴✴
Insulated assembly pipe,  
Ø 12.70 mm (1) 
✴✴
18✴✴
Insulated assembly pipe,  
Ø 15.88 mm (1) 
✴✴
24✴✴
Drain Hose, 2 m long (1)
Pipe clamp A (3)
Pipe clamp B (3)
Vinyl tape (2)
Putty 100 g (1) 
PE T3 foam tube insulation (1)
M4 x 25 tapped screw (6)
Drain plug (1)
Cement nail (6)
4-wire assembly cable (1)
✴✴
09/10/12/13/18✴✴
3-wire power cable (1)
✴✴
24✴✴
1-wire assembly cable (1)
✴✴
24✴✴
Accessories in the outdoor unit package
Rubber leg (4)
  NOTE
• A flare nut is attached to the end of each pipe of an 
evaporator or a service port. Use flare nuts when 
connecting the pipes.
• Wire assembly cables are optional. If they are not 
supplied, use standard cables.
• The drain plug and the rubber legs are included only 
when the air conditioner is supplied without assembly 
pipes. 
• If these accessories are supplied, they are in the 
accessory package or outdoor unit package.
Tools
 
General tools
•  Vacuum pump  
(Backward flowing 
prevention)
•  Manifold gauge
•  Stud finder
•  Torque wrench
•  Pipe cutter
•  Reamer
•  Pipe bender
•  Spirit level
•  Screwdriver
•  Spanner
•  Drill
•  L-wrench
•  Measuring tape
Tools for test operation
• Thermometer
• Resistance meter
• Electroscope
Step 1.4  Drilling a hole through the 
wall
Before fixing the installation plate to a wall and then 
fixing the indoor unit to the installation plate, a window 
frame, or a gypsum board, you must determine the 
position of a hole (with 65 mm inner diameter) through 
which the pipe bundle (consisting of power and 
communication cables, refrigerant pipes, and drain hose) 
will pass and then drill that hole.
1  Determine the position of a 65 mm hole in 
consideration of the possible directions of the pipe 
bundle and the minimum distances between the hole 
and the installation plate.
Left
Right
Rear right or left
<Possible directions of the pipe bundle>
Bottom right
  CAUTION
•  If changing the pipe direction from left to right, do not 
drastically bent it but slowly turn it in the opposite 
direction as shown. Otherwise, the pipe may be damaged 
in the process.
Pipe bundle hole
<Minimum distances between the
 hole and the installation plate>
2  Drill the hole.
  CAUTION
• Be sure to drill only one hole. 
• Make sure that the hole slants downwards so that the 
drain hose slants downwards to drain water well.
Wall
Drain hose
<The hole slants downwards>
Indoor unit
Step 1.5  Taping the pipes, cables, 
and drain hose
1  Wrap foam insulation on parts without insulation 
on the ends of the refrigerant pipes, as shown in 
the figure. This wrapping minimises condensation 
problem. 
Insulation
Refrigerant pipes
2  Wind the refrigerant pipes, power cable, 
communication cable and drain hose with vinyl tape 
to make a pipe bundle. 
Refrigerant pipes 
(assembly pipe)
Installation plate
Vinyl tape
Drain hose
Power and communication cables 
(assembly cable)
Indoor Unit Installation
Step 2.1  Connecting the cables 
(assembly cable)
Control box
 (Unit : mm)
Model
A
B
C
D
✴✴ 
09/10/12/13✴✴ 
30
96
38
30
✴✴ 
18/24✴✴ 
38
126
70
38
Pipe bundle hole: Ø 65 mm
N(1) 1
2
• When performing electrical and earthing works, 
be sure to comply with the 'technical standards of 
electrical installations' and the 'wiring regulations' in 
the local regulations.
• Tighten the terminal block screw to 1.2-1.8 N•m (1.2-
1.8 kgf•cm).
  NOTE
• Each wire is labelled with the corresponding terminal 
number.
• Use shield cable (Category 5; less than 50pF/m) for 
noisy environmental site.
• Power supply cords of parts of appliances for outdoor 
use shall not be lighter than polychloroprene 
sheathed flexible cord. (Code designation IEC:60245 
IEC 66/CENELEC: H07RN-F, IEC: 60245 IEC 57/
CENELEC: H05RN-F, IEC: 60227 IEC53/CENELEC: 
H05VV-F)
• Power & Communication cable shall not exceed 30m.
  CAUTION
• For the terminal block wiring, use a wire with a 
ring terminal socket only. Regular wires without 
a ring terminal socket may become a hazard due 
to overheating of the electrical contact during 
installation.
• If you need to extend the pipe, be sure to extend 
the cable, too. The maximum length of each of the 
cable and pipe used should not exceed 15 meters 
(✴✴09/10/12/13✴✴) and 20 meters (✴✴18/24✴✴). 
• Do not connect two or more different cables to 
extend the length. This connection may cause fire.
• Each circular terminal must match the size of its 
corresponding screw in the terminal block.
• After connecting the cables, make sure that terminal 
numbers on the indoor and outdoor units match.
• Ensure that power and communication cables are 
separated, they must not be in the same cable.
  WARNING
• Connect the wires firmly so that wires cannot be 
pulled out easily. (If they are loose, it could cause 
burn-out of the wires.)
Step 2.2  Optional: Extending the 
power cable 
1  Prepare the following tools.
Tools
Spec
Shape
Crimping 
pliers
MH-14
Connection 
sleeve (mm)
20xØ6.5 (HxOD)
Insulation 
tape
Width 19 mm
Contraction 
tube (mm)
70xØ8.0 (LxOD)
2  As shown in the figure, peel off the shields from the 
rubber and wire of the power cable.  
• Peel off 20 mm of cable shields from the pre-
installed tube.
  CAUTION
• For information about the power cable 
specifications for indoor and outdoor units, refer to 
the installation manual.
• After peeling off the tube wire, you must insert a 
contraction tube.
Power cable
Pre-installed tube for the power cable
(Unit: mm)
(Unit: mm)
20
20
20
20
60
120
180
3  Insert both sides of core wire of the power cable into 
the connection sleeve. 
• Method 1: Push the core wire into the sleeve from 
both sides.
• Method 2: Twist the wire cores together and push it 
into the sleeve.
Connection sleeve
Connection sleeve
Method 1
Method 2
4  Using a crimping tool, compress the two points and 
flip it over and compress another two points in the 
same location.
• The compression dimension should be 8.0.
Compression 
dimension
• After compressing it, pull both sides of the wire to 
make sure it is firmly pressed.
Compress it 4 times.
5 mm
Compress it 4 times.
5 mm
Method 1
Method 2
5  Wrap it with the insulation tape twice or more and 
position your contraction tube in the middle of the 
insulation tape.  
Three or more layers of insulation are required.
Method 1
Method 2
Insulation tape
40 mm
35 mm
Insulation tape
6  Apply heat to the contraction tube to contract it.
Contraction tube
7  After tube contraction work is completed, wrap it with 
the insulation tape to finish.
Insulation tape
  CAUTION
• Make sure that the connection parts are not exposed 
to outside.
• Be sure to use insulation tape and a contraction tube 
made of approved reinforced insulating materials 
that have the same level of withstand voltage with 
the power cable. (Comply with the local regulations on 
extensions.)
 
 WARNING
• In case of extending the electric wire, please DO NOT 
use a round-shaped pressing 
socket.
 
Incomplete wire 
connections can cause 
electric shock or a fire. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Step 2.3  Installing and connecting 
the drain hose
1  Install the drain hose. 
Drain hose
Assembly pipe
Connection hose
Ditch
Water
Slant downwards
Slant upwards
Dipped in water
Bent
Too small 
clearance
Too small 
clearance
Wall
Indoor unit
Drain hose
5 cm
less
2  Pour water into the drain pan. Check whether the hose is 
well drained.  
  CAUTION
• Make sure that the indoor unit is in upright position 
when you pour water to check for leakage. Make sure 
that the water does not overflow onto the electrical 
part. 
• If the diameter of the connection hose is smaller than 
the product's drain hose, water leakage may occur.
• Inadequate installation may cause water leakage.
• If the drain hose is routed inside the room, insulate 
the hose so that dripping condensation does not 
damage the furniture or floors.
• Do not box in or cover the drain hose connection.  
Drain hose connection must be easily accessible and 
serviceable. 
Step 2.4  Optional: Extending the 
drain hose 
(A)
(B)
Drain hose (A)
Extension drain hose (B)
Drain hose
Extension drain hose
20 mm or more
Foam insulation
Vinyl tape
DB68-06570F-00
Before 
connecting
Correct
Upside 
down
Damaged
Non-
circular
After 
connecting
Correct
Correct
Upside 
down
Non-fitted
(Front view) (Side view)
<Circular terminal>
Fasten the screws for the wire holders.
Model
✴✴
09/10/12/13✴✴
✴✴
18✴✴
✴✴
24✴✴
Power cable  
(Outdoor unit)
3G x 1.0 mm², 
H05VV-F
3G x 1.5 mm², 
H05VV-F
3G x 2.5 mm², 
H05VV-F
Outdoor-to-
indoor power 
cable
4G x 1.5 mm², 
H07RN-F
4G x 1.5 mm², 
H07RN-F
3G x 2.5 mm², 
H07RN-F,
1 x 0.75 mm², 
H05RN-F
Type GL
20A
25A
25A
DB68-06570F.indd   1
12/16/2016   11:34:45 AM