2.  Press the Mode button to select Cool mode. 
X
f
In Cool mode, use  Temp + or – button and set the temperature at 32  °C. 
•  Approximately 3~5 minutes later, outdoor unit will start to 
operate and the Cool air will blow out.
•  After 12 minutes of stationary condition check the indoor unit 
air treatment.
NOTE
Cooling mode (indoor unit check)  Inlet air temp. - Outlet air temp:  
From 10 °C to 12 °C (indicative delta T)
Cooling mode (indoor unit check)  Inlet air temp. - Outlet air temp:  
From 11 °C to 14 °C (indicative delta T)
In heating mode, the indoor fan motor can remain off to avoid cold air blown 
into conditioend space.
3.  Press the Air swing  , 
 button and check the following:
X
f
The airflow blades work properly.
4.  Press the Power   button to stop the operation.
•  When you complete the installation successfully, hand over this manual to the user for storage in a handy and 
safe place.
NOTE
Pump down procedure (when removing the product)
1.  Turn on the air conditioner and select Fast Cool mode. Please let the compressor run for more than 5 minutes. If the 
compressor does not operate for more than 5 minutes due to protection control, wait about 2 minutes, and then carry 
out the next procedure. 
2.  Release the valve caps on High and Low pressure side.  
3.  Use L wrench to close the valve on the high pressure side.  
4.  Approximately 2 minutes after, close the valve on the low pressure side. 
5.  Stop operation of the air conditioner by pressing the Power button on the indoor unit or remote controller. 
6.  Disconnect the pipes.