Canon ir2016, ir2020 マニュアル

ページ / 56
Chapter 4
4-7
4.4.6 <011: T.30 T1 timer (for reception)>
0011-0070
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant signal is received).
4.4.7 <013: T.30 EOL timer>
0011-0071
Set it so that the 1-line transmission time is longer for reception to prevent reception errors caused by a long data length per line (e.g., computer FAX).
4.4.8 <016: time length to first response at time of fax/tel switchover>
0011-0073
Allows setting of the time from seizing the line till pseudo RBT is sent, when the Fax/ Tel switching function is operating.
4.4.9 <017: pseudo RBT signal pattern ON time length><018: pseudo RBT signal pattern OFF time length (short)><019: 
pseudo RBT signal pattern OFF time length (long)>
0011-0074
Use it to set the pattern of the pseudo RBT signal transmitted at time of a fax/tel switchover.
4.4.10 <020: pseudo CI signal pattern ON time length><021: pseudo CI signal pattern OFF time length (short)><022: pseudo 
CI signal pattern OFF time length (long)>
0011-0075
Use it to set the pseudo CI signal pattern transmitted at time of a fax/tel switchover.
4.4.11 <023: CNG detention level for fax/tel switchover>
0011-0076
Use it to set the CNG detention level for a fax/tel switchover.
4.4.12 <024: pseudo RBT transmission level at time of fax/tel switchover>
0011-0077
Use it to set the pseudo transmission level for a fax/tel switchover.
4.4.13 <025: Answering machine connection function signal detection time>
0011-0079
Sets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-
tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.
4.4.14 <027: V.21 low-speed flag preamble identification length>
0011-0078
Use it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific period
of time.
4.5 Setting of Destination (TYPE)
4.5.1 Overview
0011-0081
#NCU data is automatically set to be in compliance with the communication standard in each country/region depending on TYPE settings.
Memo: 
#CLEAR has items of TYPE setting.
4.6 Setting of Printer Functions (PRINTER)
4.6.1 Setting of Bit Switch (SSSW)
4.6.1.1 SSSW-SW05: Setting of Reduction/Cassette Selection
4.6.1.1.1 List of Functions
0011-0082
T-4-15
4.6.1.1.2 Detailed Discussions of Bit 7
0011-0083
Use it to enable/disable placement of priority on recording in sub scanning direction.
T-4-16
*: Image B4 or shorter and that cannot be printed by division and on A4 recording paper.
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
not used
-
-
3
not used
-
-
4
not used
-
-
5
not used
-
-
6
not used
-
-
7
priority on recording in sub scanning direction
place
do not place
place:
if B4 recording paper and A4 recording paper are set and an A4 extra-long image 
(*) is received, printing will be on the B4 recording paper.
do not place:
if B5 horizontal recording paper and A4 recording paper are set and a B4 image is 
received, printing will be by division and on B5 horizontal recording paper.