SNMP Commands
snmp config
Show/set global Simple Network Management Protocol (SNMP) parameters.
SYNTAX:
EXAMPLE (default configuration):
snmp config
[RWCommunity = <string>]
[ROCommunity = <string>]
[sysContact = <quoted string>]
[sysName = <quoted string>]
[sysLocation = <quoted string>]
[ROCommunity = <string>]
[sysContact = <quoted string>]
[sysName = <quoted string>]
[sysLocation = <quoted string>]
RWCommunity
The read-write community name.
By default the read-write community name is private.
By default the read-write community name is private.
OPTIONAL
ROCommunity
The read-only community name.
By default the read-only community name is public.
By default the read-only community name is public.
OPTIONAL
sysContact
The SNMP system contact.
By default the system contact is Service Provider.
By default the system contact is Service Provider.
OPTIONAL
sysName
The SNMP system name.
By default the system name is SpeedTouch™ 610.
By default the system name is SpeedTouch™ 610.
OPTIONAL
sysLocation
The SNMP system location.
By default the system location is Customer Premises.
By default the system location is Customer Premises.
OPTIONAL
=>snmp config
Read-write SNMP community name
:
private
Read-only
SNMP community name
:
public
SNMP System Contact
: Service Provider
SNMP System Name
:
SpeedTouch 610
SNMP System Location
: Customer Premises
=>