Omnitron 7333-1 ユーザーズマニュアル
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • info@omnitron-systems.com • 140 Technology Dr., Irvine CA 92618
Page 4
©2010 Omnitron Systems Technology, Inc. All rights reserved.
iConverter
and
NetOutlook
are registered trademarks of Omnitron Systems Technology, Inc.
FlexPoint,
miConverter
and
OmniConverter
are trademarks of Omnitron Systems Technology, Inc.
Trademarks are owned by their respective companies. Specifications subject to change without notice.
091-17100-001H
9/10
Ordering inFOrmatiOn
Model
Application
Distance
(km)
Wavelength
(nm)
Center
Wavelength
(nm)
Typical
Loss
1
(db/km)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx
Sense
(dBm)
Max. Rx
Power
(dBm)
Min.
Attenuation
(dBm)
Link
Budget
(dBm)
Calc.
Distance
2
(km)
7327E-1
25
1270
1271
0.37
-3
1
-14
0.5
0.5
11
25.4
7329E-1
25
1290
1291
0.35
-3
1
-14
0.5
0.5
11
26.9
7331E-1
25
1310
1311
0.33
-3
1
-14
0.5
0.5
11
28.5
7333E-1
25
1330
1331
0.32
-3
1
-14
0.5
0.5
11
29.4
7335E-1
25
1350
1351
0.31
-3
1
-14
0.5
0.5
11
30.3
7337E-1
25
1370
1371
0.33
-3
1
-14
0.5
0.5
11
28.5
7339E-1*
25
1390
1391
0.48
-3
1
-14
0.5
0.5
11
19.6
7341E-1
25
1410
1411
0.33
-3
1
-14
0.5
0.5
11
28.5
7343E-1
25
1430
1431
0.27
-3
1
-14
0.5
0.5
11
34.8
7345E-1
25
1450
1451
0.24
-3
1
-14
0.5
0.5
11
39.2
7327E-2*
40
1270
1271
0.37
1
5
-15
0
5
16
37.8
7329E-2
40
1290
1291
0.35
1
5
-15
0
5
16
40
7331E-2
40
1310
1311
0.33
1
5
-15
0
5
16
42.4
7333E-1
40
1330
1331
0.32
1
5
-15
0
5
16
43.8
7347E-2
40
1470
1471
0.22
-3
1
-14
0.5
0.5
11
42.7
7349E-2
40
1490
1491
0.21
-3
1
-14
0.5
0.5
11
44.8
7351E-2
40
1510
1511
0.2
-3
1
-14
0.5
0.5
11
47
7353E-2
40
1530
1531
0.19
-3
1
-14
0.5
0.5
11
49.5
7355E-2
40
1550
1551
0.19
-3
1
-14
0.5
0.5
11
49.5
7357E-2
40
1570
1571
0.19
-3
1
-14
0.5
0.5
11
49.5
7359E-2
40
1590
1591
0.19
-3
1
-14
0.5
0.5
11
49.5
7361E-2
40
1610
1611
0.19
-3
1
-14
0.5
0.5
11
49.5
Fiber CWDM SFP+s for devices that support 10 Gigabit Ethernet, and compatible with the iConverter XG.
Model
Application
Distance
(km)
Wavelength
(nm)
Center
Wavelength
(nm)
Typical
Loss
1
(db/km)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx
Sense
(dBm)
Max. Rx
Power
(dBm)
Min.
Attenuation
(dBm)
Link
Budget
(dBm)
Calc.
Distance
2
(km)
7527-1
25
1270
1271
0.37
-3
1
-14
0.5
0.5
11
25.4
7529-1
25
1290
1291
0.35
-3
1
-14
0.5
0.5
11
26.9
7531-1
25
1310
1311
0.33
-3
1
-14
0.5
0.5
11
28.5
7533-1
25
1330
1331
0.32
-3
1
-14
0.5
0.5
11
29.4
7535-1
25
1350
1351
0.31
-3
1
-14
0.5
0.5
11
30.3
7537-1
25
1370
1371
0.33
-3
1
-14
0.5
0.5
11
28.5
7539-1*
25
1390
1391
0.48
-3
1
-14
0.5
0.5
11
19.6
7541-1
25
1410
1411
0.33
-3
1
-14
0.5
0.5
11
28.5
7543-1
25
1430
1431
0.27
-3
1
-14
0.5
0.5
11
34.8
7545-1
25
1450
1451
0.24
-3
1
-14
0.5
0.5
11
39.2
7527-2
40
1270
1271
0.37
1
5
-15
0
5
16
37.8
7529-2
40
1290
1291
0.35
1
5
-15
0
5
16
40
7531-2
40
1310
1311
0.33
1
5
-15
0
5
16
42.4
7533-2
40
1330
1331
0.32
1
5
-15
0
5
16
43.8
7547-2
40
1470
1471
0.22
-3
1
-14
0.5
0.5
11
42.7
7549-2
40
1490
1491
0.21
-3
1
-14
0.5
0.5
11
44.8
7551-2
40
1510
1511
0.2
-3
1
-14
0.5
0.5
11
47
7553-2
40
1530
1531
0.19
-3
1
-14
0.5
0.5
11
49.5
7555-2
40
1550
1551
0.19
-3
1
-14
0.5
0.5
11
49.5
7557-2
40
1570
1571
0.19
-3
1
-14
0.5
0.5
11
49.5
7559-2
40
1590
1591
0.19
-3
1
-14
0.5
0.5
11
49.5
7561-2
40
1610
1611
0.19
-3
1
-14
0.5
0.5
11
49.5
1
Based on Corning SMF-28 single-mode fiber optic cable.
2
Calculated distance includes a 2dB margin.
* Calculated distance does not meet specification distance.
Consult the factory for industrial temperature (-40
Consult the factory for industrial temperature (-40
O
C to +85
O
C) models
CWDM Optical Transceivers
Fiber CWDM XFPs for devices that support 10 Gigabit Ethernet and SONET OC-192 network protocols
and compatible with the iConverter XG