ASUS TS500-E5 ユーザーズマニュアル

ページ / 164
ASUS TS500-E5
6-25
6.2.6 
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected logical 
drive. The utility can automatically detect and/or detect and correct any differences 
in data redundancy depending on the selected option in the Objects > Adapter 
menu.
The Check Consistency command is available only for logical drives included 
in a RAID 1 set.
Using the Check Consistency
To check data consistency using the Check Consistency command:
1.  From the Management Menu, select Check Consistency, then press 
<Enter>.
2.  The screen displays the available RAID set(s) and prompts you to select the 
logical drive to check. Press the <Spacebar> to select the logical drive from 
the Logical Drive selection, then press <F10>.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure
 
Initialize 
Objects 
Rebuild 
Check Consistency
CC Of VD(s)
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
SPACE-(De)Select, F10-Check Consistency
Management Menu
Configure
 
Initialize 
Objects 
Rebuild 
Check Consistency
Select VD
Logical Drive(s) Configured
LD    RAID    Size    #Stripes    StripSz   Status
0      10   154494MB     4        64 KB     ONLINE
Logical Drives
Loical Drive 0