6-30
Chapter 6: RAID configuration
6.2.9 
Enabling the WriteCache
You may enable the RAID controller’s WriteCache option to improve the data 
transmission performance.
When you enable WriteCache, you may lose data when a power interruption 
occurs while transmitting or exchanging data among the drives.
To enable WriteCache:
1.  From the Management Menu, select Objects > Adapter, then press <Enter> 
to display the adapter properties.
2.  Select WriteCache, then press <Enter> to turn the option On (enabled).
3.  When finished, press any key to continue.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure 
Initialize 
Objects
 
Rebuild 
Check Consistency
Disk Write Cache - Off(Write Through) or On(Write Back)
Objects
Adapter
 
Virtual Drive 
Physical Drive
Adapter 0
Rebuild Rate   = 30 
Chk Const Rate = 30 
FGI Rate       = 30 
BGI Rate       = 30 
Disk WC        = Off
 
Read Ahead     = On 
Bios State     = Enable 
Stop On Error  = No 
Fast Init      = Enable 
Auto Rebuild   = On 
Auto Resume    = Enable 
Disk Coercion  = 1GB 
Factory Default