Install the Router and Configure Software
Install the Router without Using a Mechanical Lift
107
5.
Grasp both sides of the SCB and slide it about halfway out of the chassis.
6.
Place one hand under the SCB to support it, slide it completely out of the chassis, and 
place it on the antistatic mat or in the electrostatic bag prepared in Step 1.
Figure 33:  Remove the SCB
Remove the Air Filter
 
The air filter is located below the craft interface at the front of the chassis (see Figure 1). The 
air filter weighs less than 0.5 lb (0.2 kg), but you must remove it in order to remove the lower 
impeller assembly.
To remove the air filter, follow this procedure (see Figure 34):
1.
Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on 
the chassis.
2.
Grasp the sides of the air filter and firmly pull it out from the chassis.
1052
Thumbscrew
Extractor clip