Instructions for use
The AVENT i
Q24™ Electronic Steam Steriliser is one of a new
generation of intelligent products from AVENT – the most
sophisticated steam steriliser you can buy and the easiest to use.
The AVENT i
Q24 Steriliser uses the intensive heat of steam to kill all
household germs helping you sterilise your baby feeding equipment
as safely and quickly as possible. There are two different modes for
greater convenience:
Mode 1 runs a single 6 minute sterilising cycle, then keeps the
contents sterile for 6 hours, providing the lid is not removed.
Mode 2 keeps contents sterile for up to 24 hours by continuously
repeating the cycle, so you can have clean, sterile bottles day 
and night.
As well as bottles and breastfeeding accessories, you can sterilise any
other boilable items (please refer to the manufacturer’s instructions
regarding sterilisation).
Please take a few minutes to read through the ENTIRE INSTRUCTION
LEAFLET 
before using your AVENT i
Q24 Steriliser for the first time.
PLEASE SAVE THESE INSTRUCTIONS. Also available at www.avent.com
Contents 
(see diagram A, page 2)
a) Lid
f) Steriliser body
b) Upper basket
g) Measuring Cup
c) Bottle rack
h) De-scaler (citric acid)
d) Lower basket (same as b)
i) Tongs
e) Central stem
j) Lead and plug
Before using your steriliser for the first time
(see diagram B and refer to the Electronic Display Guide opposite)
Remove all items from inside the steriliser body. 
1. Measure exactly 90ml of water and pour in.
2.  Assemble the blue components (baskets, stem and bottle rack) 
and place into the steriliser. Put the lid on.
3. Connect the lead into the back of the steriliser and plug into the
mains supply.
4. The unit will display a flashing ‘0’ to indicate you need to select
a mode. One short press of the control button will display a
flashing ‘1’. Hold the control button in for 2 seconds then release,
and a rotating ‘0’ is displayed. Mode 1 is now in progress.
5. After the water has reached 100°C, it will turn to steam. When the
sterilising cycle is almost complete a numerical countdown will be
displayed.
6. At the end of the cycle the unit will beep 5 times. Three bars will
flash and then remain displayed.
7. Let the steriliser cool down for 3 minutes. Unplug and disconnect
the lead from the back of the steriliser.
8.  Remove the blue components and empty any remaining water
from the unit. Wipe dry. The steriliser is now ready for use.
Sterilising in Mode 1 – 6 hour sterile period
Sterilising in Mode 2 – 24 hour sterile period
(see diagram C, page 3)
To sterilise up to six 125ml, 260ml or 330ml AVENT Bottles
Before each use, wash items in mild soapy water and rinse.
1. Measure and pour in exactly 90ml of water if selecting Mode 1 
OR 200ml of water if selecting Mode 2.
2. Slide the lower basket onto the central stem. Thread 2 screw rings
onto the central stem. Slide the bottle rack down the central stem,
with the neck facing down, until it rests on the top screw ring.
3.  Place the teats through the centre of the holes in the bottle rack
onto the lower basket. Thread 4 screw rings onto the central stem.
4.  Place inverted bottles in the bottle rack and push the upper basket
onto the central stem until it rests on the catch. Place dome caps
and tongs into the upper basket.
5. The upper basket is not required when sterilising 330ml bottles.
6. Place the assembled unit into the steriliser body and put the lid on.
Put the lead into the back of the steriliser body and plug into the
mains supply. A flashing ‘0’ will appear, indicating that you need to
select a mode. 
7. To select Mode 1, press the control button once and the mode
number will be displayed. To run this mode, hold the control button
in for 2 seconds, then release. A rotating ‘0’ will be displayed. 
Mode 1 is now in progress.
OR
To select Mode 2, press the control button twice and the mode
number will be displayed. To run this mode, hold the control button
in for 2 seconds, then release. Three ascending and descending bars
will be displayed. Mode 2 is now in progress.
8. Do not remove the lid until the 6 minute sterilising cycle has
ended. This is indicated by 5 beeps and 3 bars being displayed.
Items will remain sterile for up to 6 hours provided the lid is not
removed. After 2 hours, the display will show 2 bars and, after a
further 2 hours, one bar. To indicate the end of Mode 1 or 2, the
unit will sound a long beep followed by a flashing ‘0’†. At this point
items should be used immediately or re-sterilised. (Please refer to
‘To remove sterilised items during or after a cycle’). Unplug the lead
from the back of the steriliser. Pour away any remaining water,
rinse out the inside of the steriliser body and wipe dry.
† The end of a cycle is 6 hours after commencement of Mode 1 and 
24 hours after commencement of Mode 2. The unit can be completely
stopped at any time during a cycle, by pressing and holding in the
control button for 2 seconds. The unit will beep and a flashing ‘0’ will
be displayed, indicating the unit has returned to selection mode.
To load the AVENT ISIS
Breast Pump
(see diagram D page 3)
Before each use, wash items in mild soapy water and rinse.
1. Disassemble the ISIS Breast Pump and click the pump body into 
the slot in the upper basket and arrange the other breast pump
components as shown. 
2. Place remaining components of the pump in the lower basket.
3. Up to six 125ml or 260ml bottles (not including screw rings, 
teats or dome caps) can be sterilised with the pump.
4. Follow sterilising instructions.
To remove sterilised items during or after a cycle
(see diagram E page 3)
1. Let the steriliser cool down for 3 minutes after sterilising cycle
has been completed.
2. Press the control button to reset (Mode 1) or pause (Mode 2) 
the unit.
3. Wash your hands thoroughly before removing the sterilised items.
4. Remove the lid.
5. The tongs can be used to remove small items and to pull the sterile
teats through the screw rings of the bottles.
6. Removed items must be used/assembled immediately or 
re-sterilised. Made up feeds can be stored in the fridge for up 
to 24 hours.
7. In Mode 1, the steriliser must be left to cool for at least
10 minutes between each use.
8. In Mode 2 – items can be removed/replaced and then the cycle
restarted. To restart, press the control button. The unit will
immediately enter a new sterilisation phase and continue the 
24 hour cycle from where it was interrupted. If unplugged the
countdown cycle will stop.
Dishwasher Basket
(see diagram F page 3)
1. Two baskets can be clipped together to hold small items such as
teats, breast pump parts etc. for washing in the top rack of your
dishwasher prior to sterilisation.
2. To clip together, align the baskets so that the indicators are
opposite each other and snap the baskets together. To open, 
pull apart with fingers.
Warning: Your AVENT items may discolour over time if they are
washed in the dishwasher with dirty items covered with remnants
of strong sauces, such as tomato sauce.
Care of your steriliser
Using pre-boiled or filtered water in your AVENT iQ24 Steriliser can
reduce limescale build up. You should de-scale your steriliser every
four weeks, or as often as needed in hard water areas, to ensure it
continues to work 100% effectively. 
EITHER:
1. Mix one sachet of citric acid* (10gms) with 200ml of water. 
Pour into the empty steriliser. Do not put lid on. Activate Mode 1
and leave for 1-2 minutes. Unplug and leave to stand for 30
minutes. Drain and rinse the inside of the steriliser. Then in 
Mode 1, run a full sterilising cycle empty with the lid on, using
exactly 90ml of water. Drain and wipe dry. 
OR:
2. Pour 100ml vinegar mixed with 200ml cold water into the steriliser.
Allow to stand in the unit until any limescale has dissolved. 
Drain and rinse the inside of the steriliser thoroughly. Wipe dry.
*Citric Acid is available from most chemists – avoid contact with eyes
as this may cause irritation. Keep out of reach of children.
GB
GB
Electronic Display Guide
Steriliser plugged in and 
ready for mode selection
Ready for 
Mode 1 selection
Mode 1 sterilisation 
in progress – 
indicated by a beep 
and rotating ‘0’ 
Mode 2 sterilisation 
in progress – 
indicated by a beep 
and three ascending 
and descending bars
Numerical countdown indicates 
sterilisation almost complete (Mode 1 only)
BEEP
BEEP
Ready for 
Mode 2 selection
BEEP
BEEP
BEEP
5
Sterilisation complete – indicated 
by 5 beeps and three flashing bars – 
items will remain sterile for up to 
6 hours provided the lid is not opened 
Up to 
6 hours sterile time remaining
Up to 
4 hours sterile time remaining
Up to 
2 hours sterile time remaining
BEEP
Mode 1 or 2 complete – indicated 
by a long beep and a flashing ‘0’
BEEP
Water level too high. 
See ‘Troubleshooting’ below
Water level too low. 
See ‘Troubleshooting’ below
BEEP
Steriliser will not work 
Excessive steam escaping 
from under the lid 
Sterilising cycle takes too long 
Flashing
lower 
and side 
bars, and beep
Flashing
top and
side bars,
and beep
Check that the mains lead is connected to the steriliser as well as plugged into the mains.
Check fuse in plug.
Parts incorrectly loaded. Refer to instructions on page 4.
The steriliser is loaded with only a few items – light loads will take longer to cycle.
Insufficient water has been placed in the steriliser. Switch off, remove water, (take care if the
steriliser body is hot) and replace with 90ml of water for use with Mode 1 OR 200ml of water
for use with Mode 2. Restart the unit.
An excessive amount of water has been placed in the steriliser. Switch off, remove water, (take
care if the steriliser body is hot) and replace with 90ml of water for use with Mode 1 OR 200ml
of water for use with Mode 2. Restart the unit.
BEEP
BEEP
Troubleshooting Guide
WARNINGS
• Ensure the steriliser is placed on a firm level surface when in use.
• When in use, the steriliser contains boiling water and steam
escapes from the vent in the lid.
• Never place items on top of the steriliser.
• Take care when opening as steam can burn.
• During the sterilising cycle the lid and the steriliser body are 
very hot.
• Always keep out of reach of children.
• Never open the unit during the 6 minute sterilising cycle. Items
are not sterile if the 6 minute sterilising cycle is interrupted.
• To completely stop the steriliser at any time during a cycle, press
and hold the control button for 2 seconds to return to selection
mode or, unplug at the mains.
• Always disconnect the lead from the back of the steriliser before
pouring away water and/or rinsing.
• Always unplug from the mains supply when not in use.
• The power supply must be removed from the unit for it to be
completely switched off.
• Never immerse the steriliser in water.
• Never use the steriliser without water.
• Do not use bleach or chemical sterilising solutions/tablets in your
steam steriliser or on products to be sterilised.
• Do not use abrasive, anti-bacterial materials or scourers to clean
the steriliser.
• Do not use softened water in the steriliser.
• The lead supplied must not be used on any other appliance and no
other lead should be used with the AVENT iQ24™ Steriliser.