ADC H2TU-C-231 ユーザーズマニュアル

ページ / 74
Appendix A - Specifications
LTPH-UM-1109-01, Issue 1
54
January 9, 2002
H2TU-C-231 List 2
A
PPENDIX
A - S
PECIFICATIONS
Power
HDSL2 Span Voltage
0 or -180 Vdc ±5 Vdc
CO Supply
-48 Vdc nominal (-42.5 to -56.5 Vdc) 
(See 
, and 
.)
Electrical Protection
Secondary surge and power cross-protection on HDSL2 ports. Requires external 
primary protection.
Fusing
Internal, connected to fuse alarm output on pin 32
Environmental
Operating Temperature
-40°F to +149°F (-40°C to +65°C)
Operating Humidity
5% to 95% (non-condensing)
Physical
Height
5.9 in. (15.0 cm)
Width
1.4 in. (3.5 cm)
Depth
10.0 in. (25.4 cm)
Weight
8.0 oz. (0.23 kg)
Mounting
220 mechanics high-density shelf
HDSL2
Line Rate
1.552 Mbps Overlapped Pulse Amplitude Modulation Transmission with Interlocking 
Spectra (OPTIS)
Transmission
Full duplex
Media
One non-loaded, copper, two-wire cable pair
Output
+16.8 dBm ±0.5 dBm at 135
Ω 
(0-450 kHz)
 
at CO side; 
+16.5 dBm ±0.5 dBm at 135
Ω 
(0-350 kHz) at remote side
Line Impedance
135
Ω
Maximum Loop Attenuation
35 dB at 196 kHz, 135
Ω
Start-up Time
30 sec. (typical), 1 min. (maximum) 
DSX-1
Line Impedance
100
Ω 
Line Rate
1.544 Mbps ±200 bps
Line Format
Alternate Mark Inversion (AMI) or Bipolar with 8-Zero Substitution (B8ZS)
Frame Format
Extended SuperFrame (ESF), SuperFrame (SF), or Unframed (UNFR)
Pulse Output
6 V
pk-pk
 pre-equalized for 0 to 655 feet of ABAM cable
Input Level
+1.5 to -7.5 dB DSX
System
One-way DS1 Delay
<400 µs
Wander (Looped)
Meets MTIE T1.101 requirements
Wideband Jitter (Looped)
0.2 UI maximum
Narrowband Jitter (Looped)
0.1 UI maximum