HP dl385 ユーザーズマニュアル

ページ / 112
 
Component identification  15 
 
Systems Insight Display 
LED and color 
Internal Health LED color 
Status 
Processor failure, socket X  
(amber) 
Red 
One or more of the following conditions may 
exist: 
 
Processor in socket X has failed. 
 
Processor X is not installed in the socket. 
 
Processor X is unsupported. 
 
ROM detects a failed processor during 
POST. 
 
Amber 
Processor in socket X is in a pre-failure 
condition. 
PPM failure (amber) 
Red 
One or more of the following conditions may 
exist: 
 
PPM for processor 2 has failed. 
 
PPM is not installed, but processor 2 is 
installed. 
I-PPM failure (amber) 
Red 
Embedded I-PPM for processor 1 has failed. 
DIMM failure, slot X (amber)  Red 
One or more of the following conditions may 
exist: 
 
DIMM in slot X has failed. 
 
Memory group is populated with different 
DIMM types (all DIMMs are mismatched). 
 
Amber 
One or more of the following conditions may 
exist: 
 
DIMM in slot X is in a pre-failure condition.
 
Memory group is populated with different 
DIMM types (at least one DIMM is good). 
DIMM failure, all slots in one 
bank (amber) 
Red 
One or more DIMMs has failed. Test each 
bank of DIMMs by removing all other DIMMs. 
Isolate the failed DIMM by replacing each 
DIMM in a bank with a known working 
DIMM. 
DIMM failure, all slots in all 
banks (amber) 
Red 
One or more DIMMs has failed. Test each 
bank of DIMMs by removing all other DIMMs. 
Isolate the failed DIMM by replacing each 
DIMM in a bank with a known working 
DIMM. 
Overtemperature (amber) 
Red 
The server has detected a hardware critical 
temperature level. 
Fan (amber) 
Amber 
One fan has failed in redundant mode. 
 
Red 
One or more of the following conditions may 
exist: 
 
One fan has failed in non-redundant mode
 
The minimum fan requirements are not 
being met. Two or more fans have failed 
or are missing.