HP ml350 ユーザーズマニュアル

ページ / 91
 
Removal and replacement procedures  63 
9. 
Close the heatsink locking levers. 
 
10. 
Connect the heatsink fan cable to the system board. 
  
 
IMPORTANT:
  Install all components with the same configuration that was used on the failed 
system board. 
  
11. 
Install all components removed from the failed system board. 
12. 
Install the access panel. 
13. 
Do one of the following: 
Install and lock the bezel. 
Slide the server back into the rack. 
14. 
Power up the server. 
After you replace the system board, you must re-enter the server serial number and the product ID. 
1. 
During the server startup sequence, press the F9 key to access RBSU. 
2. 
Select the System Options menu. 
3. 
Select Serial Number. The following warning is displayed:   
WARNING! WARNING! WARNING! The serial number is loaded into the system 
during the manufacturing process and should NOT be modified. This option 
should only be used by qualified service personnel. This value should 
always match the serial number sticker located on the chassis.   
4. 
Press the Enter key to clear the warning. 
5. 
Enter the serial number and press the Enter key. 
6. 
Select Product ID. 
7. 
Enter the product ID and press the Enter key. 
8. 
Press the Esc key to close the menu. 
9. 
Press the Esc key to exit RBSU. 
10. 
Press the F10 key to confirm exiting RBSU. The server will automatically reboot.