Introduction 
Integrated Administrator 
The ProLiant BL e-Class Integrated Administrator provides centralized, remote management 
and monitoring for the ProLiant BL e-Class server blade enclosure, interconnect switch 
module, and 20 server blades. The Integrated Administrator acts as a combination terminal 
server and remote power controller, enabling out-of-band, secure, serial console connections 
to all server blades in the enclosure.  
The Integrated Administrator serves as a single access point for administrative functions. It 
provides remote and local setup, deployment, and administrative support, as well as 
monitoring and health reporting of server blades, interconnect switch modules, and other 
components in the enclosure, such as power supplies and fans.
 
Interconnect Switch Modules 
Two interconnect switch modules (Switch A and Switch B) in the interconnect switch 
provide switch redundancy and redundant paths to the network ports on the server blades. 
Each interconnect switch has two GB uplink ports and direct connections to one of the two 
network interface cards (NICs) (NIC 1 and NIC 2) on each server blade. The interconnect 
switch reduces as many as forty 10/100 Ethernet ports on the server blade into  
as few as one (up to four) Gigabit uplink ports on the back of the system. 
Redundant Crosslinks 
The two interconnect switch modules are connected through redundant 100-Mb crosslinks. 
These two crosslinks provide an aggregate throughput of 200 Mb for traffic between the 
switch modules.  
Redundant Paths to Server Blades 
The NICs of each server blade are routed through the enclosure’s centerwall assembly to 
different switch modules. By default, NIC 1 on each server blade is routed to Switch A and 
NIC 2 on each server blade is routed to Switch B. This configuration provides redundant 
paths to each server. 
 
IMPORTANT:  On a heavily used system, using a single uplink port for all 40 NICs can cause a traffic 
bottleneck. For example, if uplink 1 on Switch A is the only uplink used, all traffic to and from NIC 2 on 
any of the server blades must travel over the crosslinks between Switch A and Switch B. This path to 
the server blade NICs is intended as a failover route and should not be used as a primary path. For 
optimum performance, use uplink ports from both switch modules. 
 
HP ProLiant BL e-Class C-GbE Interconnect Switch User Guide 
1-5 
  
 
HP CONFIDENTIAL Codename: DeLorean Part Number: 263682-002 Last Saved On: 2/5/03 10:39 AM