HP proliant dl380 g7 633407-001 ユーザーズマニュアル

ページ / 110
 
Component identification  101 
1 Green LED 
2 Amber LED 
Interpretation 
Off 
Off 
The flash code is corrupt. 
 
 
Hot-plug fans 
  
 
CAUTION: 
 To avoid damage to server components, fan blanks must be installed in fan bays 5 
and 6 in a single-processor configuration. 
  
The only two valid fan configurations are listed in the following table. 
 
Configuration 
Fan bay 1  Fan bay 2  Fan bay 3  Fan bay 4  Fan bay 5  Fan bay 6 
1 processor 
Fan 
Fan 
Fan 
Fan 
Fan blank 
Fan blank 
2 processors 
Fan 
Fan 
Fan 
Fan 
Fan 
Fan 
 
 
For a single-processor configuration, four fans and two blanks are required in specific fan bays for 
redundancy. A fan failure or missing fan causes all fans to spin at high speed. A second fan failure or missing 
fan causes an orderly shutdown of the server. 
Installing more than the required number of fans in a single-processor configuration is not a supported 
configuration. 
For a dual-processor configuration, six fans are required for redundancy. A fan failure or missing fan causes 
all fans to spin at high speed. A second fan failure or missing fan causes an orderly shutdown of the server. 
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change 
requires a fan speed increase to cool the server. The server shuts down during the following 
temperature-related scenarios: 
 
At POST and in the OS, iLO 3 performs an orderly shutdown if a cautionary temperature level is 
detected. If the server hardware detects a critical temperature level before an orderly shutdown occurs, 
the server performs an immediate shutdown. 
 
When the Thermal Shutdown feature is disabled in RBSU, iLO 3 does not perform an orderly shutdown 
when a cautionary temperature level is detected. Disabling this feature does not disable the server 
hardware from performing an immediate shutdown when a critical temperature level is detected.