HP proliant dl380 ユーザーズマニュアル

ページ / 113
 
Component identification  20 
LED3 pattern 
LED4 pattern 
Interpretation 
— 
One blink per 
second 
The battery pack is below the minimum charge level and is being 
charged. Features that require a battery (such as write cache, 
capacity expansion, stripe size migration, and RAID migration) are 
temporarily unavailable until charging is complete. The recharge 
process takes between 15 minutes and two hours, depending on the 
initial capacity of the battery. 
— Steady 
glow 
The battery pack is fully charged, and posted write data is stored in 
the cache. 
— Off The battery pack is fully charged, and there is no posted write data 
in the cache. 
One blink per 
second 
One blink per 
second 
An alternating green and amber blink pattern indicates that the 
cache microcontroller is executing from within its boot loader and 
receiving new flash code from the host controller. 
Steady glow 
— 
There is a short circuit across the battery terminals or within the 
battery pack. BBWC features are disabled until the battery pack is 
replaced. The life expectancy of a battery pack is typically more 
than three years. 
One blink per 
second 
— 
There is an open circuit across the battery terminals or within the 
battery pack. BBWC features are disabled until the battery pack is 
replaced. The life expectancy of a battery pack is typically more 
than three years. 
 
 
Hot-plug fans (6-fan configuration)