HP proliant blade bl460c ユーザーズマニュアル

ページ / 33
System Unit
Dimensions (H x W x D)
(with bezel)
7.154 x 2.19 x 20.058 in (18.17 x 5.56 x 50.95 cm)
Weight
(approximate)
Maximum
(all hard drives and
processors installed)
14.20 lb (6.44 kg)
Minimum
(one hard drive and
processor installed)
10.75 lb (4.87 kg)
Power Specifications
For power specifications including Input Requirements, BTU Rating, and
Power Supply Output, please see the HP BladeSystem c-Class
Infrastructure QuickSpecs located at URL:
To review typical system power ratings use the HP BladeSystem Power
Sizer which is available via the online tool located at URL:
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Acoustic Noise
For acoustic noise specifications, please see the HP BladeSystem c-
Class Infrastructure QuickSpecs located at URL:
QuickSpecs
HP ProLiant BL460c Server Blade
Technical Specifications
DA - 12518   U.S. QuickSpecs — Version 27 — 5/12/2008
Page 31