HP ProLiant ML330 G6 ユーザーズマニュアル

ページ / 129
 
Specifications 112 
Specifications 
Environmental specifications 
   
Specification Value 
Temperature 
 
Operating
1
 10°C to 35°C (50°F to 90°F) 
Non-operating 30°C to 60°C (-22°F to 140°F) 
Maximum rate of temperature 
change 
 
Operating 
2,3
 10°C/hr 
(18°F/hr) 
Non-operating 20°C/hr 
(36°F/hr) 
Relative humidity 
(noncondensing)***
 
 
Operating 
10% to 90%
 
Non-operating 
5% to 95%
 
Maximum wet bulb temperature 
(non-condensing) 
 
Operating 28°C (82.4°F) 
Non-operating 38.7°C 
(101.7°F) 
Altitude 
 
Operating
2
 
3,050 m (10,000 ft) 
Non-operating 
9144 m (30,000 ft) 
Maximum rate of altitude 
change 
 
Operating 
3,000 m (10,000 ft) 
Non-operating 
9,144 m (30,000 ft) 
 
1
 All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048 
m (10,000 ft) is applicable. No direct sunlight is allowed. 
2
 The type and number of options installed can limit the upper limit. 
3
 System performance may be reduced if operating with a fan fault above 30ºC (86ºF). 
 
Mechanical specifications 
   
Specification Value 
Height 
20.0 cm (7.87 in) 
Depth (without bezel) 
42.70 cm (16.81 in) 
Width 
61.30 cm (24.13 in)