Canon fax basic 2000 サービスマニュアル

ページ / 381
6–13
1
2
3
4
5
6
ït
çi
FACSIMILE SYSTEM
A varistor is used as the protective circuit for overcurrent.
Though varistors normally do not allow current to pass, they turn the CML
relay
 ON when a high-voltage CI arrives from the telephone line, and so
the current is allowed to escape to the line to protect the circuit elements
from voltage rise.
Fig. 6-15   Overcurrent Protection (varistor)
ON
ON
CML relay
Varistor
P relay
DC seize
circuit
L1
L2
S relay