Canon galvano gc-251 ユーザーズマニュアル

ページ / 88
 
CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
32
3.4. Control 
Screen 
    This section explains the buttons and other items on the control screen. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
①  Connection display 
The status of RS-232 connection to the controller is displayed. 
Connected: CONNECT (green) 
Not connected: DISCONNECT (gray) 
② 
Position display 
The encoder position of each axis is displayed. 
(Unit: pulse) 
Note: Since the number of encoder pulses per rotation depends on 
the galvano motor, the relationship between the number of pulses 
and the angle also differs with the motor type. 
③ 
Axis selection 
Select an axis for control and information display. 
(#1 = Axis 1, #2 = Axis 2) 
The screen can display the information of only one axis selected 
here, although the position displayed at ② and the status displayed 
at ⑨ always show the information of both axes.   
④ 
Origin control 
(Homing to origin) 
Press this button to go to or detect the origin. 
The operation depends on the controller status. 
(During ordinary servo control) 
    Moving to the origin (where the position display is 0) 
    Invalid during high-speed serial communication 
(After servo OFF and soft reset) 
 
 
 
 

 
 
 
⑩ ⑪