CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
68
 
Parameter ID 
Parameter 
Name 
Torque Constant 
Data 
Torque constant (Unit: gf・cm / A) 
Return Value 
0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is used to set the torque constant of the motor. 
Note: Do not change this parameter. A unique value is available depending on the 
motor model. This is set at shipping. 
Related 
Command 
/Parameter 
LQ control related parameters 
    LQ Control Gain (Parameter ID = 6) 
    Total Inertia (Parameter ID = 8) 
 
Parameter ID 
Parameter 
Name 
Total Inertia 
Data 
Total inertia (Unit: 0.01 gf・cm
2
Return Value 
0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is used to set the inertia due to the motor rotation shaft and the mirror. 
Note: Be careful about the unit. Set a value of gf・cm
2
 multiplied by 100. 
Related 
Command 
/Parameter 
LQ control related parameters: 
    LQ Control Gain (Parameter ID = 6) 
    Torque Constant (Parameter ID = 8) 
 
Parameter ID 
Parameter 
Name 
Current Limit 
Data 
Current limit (Unit: %) 
Return Value 
0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is used to set the upper limit of a current command value. (Setting for 
each axis as a ratio to 10A) 
E.g.: 90% (10A × 0.9 = 9A) 
If the current remains over the upper limit for a specified time, a current saturation error 
occurs. 
Related 
Command 
/Parameter 
Bit 5 “Current Saturation” becomes 1 in error read (Command ID = 15).