Install the Router and Configure Software
Connect PIC Cables
121
Connect to an External Alarm-Reporting Device
You can connect the router to external alarm-reporting devices through the relay contacts on 
the craft interface next to the LEDs labeled 
RED ALARM
 and 
YELLOW ALARM
system condition that triggers the red or yellow alarm LED on the craft interface also 
activates the corresponding alarm relay contact. 
The alarm relay contacts accept wire of any gauge between 28-AWG and 14-AWG (0.09 and 
2.09 mm
2
) wire, which is not provided. Use the gauge of wire appropriate for the external 
device that you are connecting to the contacts. 
To connect an external device to an alarm relay contact, follow this procedure:
1.
Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.09 and 
2.09 mm
2
).
2.
Use a 2.5 mm Phillips screwdriver to loosen the small screws on the faceplate of the 
appropriate alarm relay contact—the upper contact for a device that reports high priority 
(red) alarms, or the lower contact for the device that reports lower priority (yellow) 
alarms. 
3.
Insert wires into the appropriate slots in the front of the relay contact (
NC
 means 
“normally closed,” 
C
 means “common,” and 
NO
 means “normally open”). 
4.
Attach the other end of the wires to the external device.
To attach a reporting device for the other kind of alarm, repeat Steps 1 through 4.
Connect PIC Cables
Now plug network cable into the PICs housed in the FPCs. For information about the cable 
used by the PICs supported on the M40 router, see the M20 and M40 Internet Routers PIC 
Guide
.
To connect the PIC cables into the PIC cable connectors at the front of the chassis, follow this 
procedure:
1.
Have ready a length of the type of cable used by the PIC.
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug. 
3.
Insert the cable connector into the cable connector port on the PIC faceplate (see 
Figure 50, which shows a fiber-optic connector).
Do not look directly into the ends of fiber-optic cables or 
the transceivers on the faceplate of a PIC that connects to 
fiber-optic cable. Single-mode fiber-optic cable and the 
PICs that use it (such as ATM or SONET/SDH) emit laser 
light that can damage your eyes.
Do not leave a transceiver uncovered except when 
removing or inserting the cable. The safety cap keeps the 
port clean and prevents accidental exposure to laser light.