Replace an AC Power Supply
M40 Internet Router Hardware Guide
138
Figure 53:  Remove an AC Power Supply
Install an AC Power Supply
To install an AC power supply, follow this procedure:
1.
Verify that the switch on the power supply faceplate is in the 
OFF
 (
O
) position.
2.
Locate the power cord shipped with the router, which should be appropriate for your 
geographical location (see “AC Power Cord Specifications” on page 45)
3.
Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on 
the chassis.
4.
Grasp the handle on the power supply faceplate with one hand and place the other hand 
under the unit to support it.
5.
With a finger of the hand that is grasping the handle, lift and hold up the safety interlock 
lever, which is just below the appliance inlet.
6.
While holding the safety interlock lever up, slide the power supply into the chassis until 
it contacts the backplane.
7.
Still holding the safety interlock lever up, turn the extractor/inserter clockwise until the 
power supply engages with the connectors on the backplane. 
8.
Push the safety interlock lever down.
9.
Using a Phillips screwdriver, tighten (but do not overtighten) the thumbscrew at each 
upper corner of the power supply faceplate.