Juniper CBL-M40-PWR-AU ユーザーズマニュアル

ページ / 268
Maintain and Replace the Power Supplies
Replace a DC Power Supply
141
4.
Press the power switch on the faceplate of one power supply to the 
ON
 ( 
|
 ) position. The 
green OK LED on the power supply faceplate blinks rapidly for a short time, then lights 
steadily.
5.
Press the second power switch to the 
ON
 ( 
|
 ) position and observe the LEDs on the 
second power supply faceplate. They should light as described in Step 4.
If the LEDs are not lit in the appropriate pattern after 60 seconds, repeat the power 
supply installation procedures described in “Install an AC Power Supply” on page 138
and the previous steps in this procedure.
6.
On the management device, monitor the startup process to verify that the system has 
booted properly.
Replace a DC Power Supply
A DC-powered router has two load-sharing, redundant DC power supplies. Each power supply 
is hot-removable and hot-insertable, as described in “Field-Replaceable Units (FRUs)” on 
page 4.
 When one power supply fails or is powered down, the other power supply 
automatically assumes the entire electrical load for the router. 
To replace a DC power supply, perform the following procedures:
After a power supply is turned on, it can take up to 60 
seconds for status indicators—such as LEDs on the power 
supply, show chassis commands, and messages on the 
craft interface LCD—to indicate that the power supply is 
functioning normally. Ignore error indicators that appear 
during the first 60 seconds.
The Routing Engine boots as the power supply completes 
its startup sequence. If the Routing Engine finishes booting 
and you need to power down the router again, first issue 
the CLI 
request system halt
 command. For complete 
If after powering on the power supply you must power it 
off, wait at least 60 seconds. After powering off a power 
supply, wait 60 seconds before turning it back on.