Replace a DC Power Supply
M40 Internet Router Hardware Guide
144
9.
While holding the safety interlock lever up, turn the extractor/inserter counterclockwise 
until the power supply disengages from the backplane. See Figure 58.
10. Grasp the handle on the power supply faceplate and pull firmly to slide the unit about 
halfway out of the chassis.
11. Place one hand under the power supply to support it, then slide it completely out of the 
chassis.
Figure 58:  Remove a DC Power Supply
Install a DC Power Supply
To install a DC power supply, follow this procedure:
1.
Verify that the power from the DC power source is shut off. Ensure that the voltage 
across the leads of the DC power cables that you are connecting is 0 V and that there is 
no chance that the cable leads might become active during connection.
2.
Verify that the power switch on the power supply faceplate is in the 
OFF
 (
O
) position.
3.
Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on 
the chassis.
4.
Grasp the handle on the power supply faceplate with one hand and place the other hand 
under the unit to support it.
5.
With a finger of the hand that is grasping the handle, lift and hold up the safety interlock 
lever, which is just below the power switch.
6.
While holding the safety interlock lever up, slide the power supply into the chassis until 
it contacts the backplane.
7.
Still holding the safety interlock lever up, turn the extractor/inserter clockwise until the 
power supply engages with the connectors on the backplane. See Figure 59.
8.
Push the safety interlock lever down.