Maintain and Replace the Power Supplies
Disconnect and Connect DC Power
147
15. Reinstall the protective shield covering the terminal studs.
16. Press the power switch on the power supply to the 
ON
 ( 
|
 ) position. Verify that the green 
LED labeled 
OK
 on the power supply faceplate eventually lights steadily.
Disconnect and Connect DC Power
On a DC-powered router, the power cables from the external DC power sources connect to 
terminal studs on each power supply. To disconnect or connect power to the router, perform 
the following procedures:
Disconnect DC Power from the Router
To disconnect DC power from the router, follow this procedure:
1.
On the console or other management device connected to the Routing Engine, enter CLI 
operational mode and issue the following command to shut down the router software. 
For more information, see the JUNOS Internet Software Operational Mode Command 
Reference: Protocols, Class of Service, Chassis, and Management
.
user@host> request system halt
Wait to continue until a message appears on the console confirming that the operating 
system has halted.
2.
Turn off the power flowing from each DC power source to a power supply. Ensure that 
the voltage across the leads of the DC power cables is 0 V and that there is no chance 
that they might become active during removal.
After a power supply is turned on, it can take up to 60 
seconds for status indicators—such as LEDs on the power 
supply, 
show chassis
 commands, and messages on the 
craft interface LCD—to indicate that the power supply is 
functioning normally. Ignore error indicators that appear 
during the first 60 seconds.
If the router is completely powered down when you power 
on the power supply, the Routing Engine boots as the 
power supply completes its startup sequence. If the 
Routing Engine finishes booting and you need to power 
down the router again, first issue the CLI 
request system halt
 command. For complete instructions, 
If after powering on the power supply you must power it 
off, wait at least 60 seconds. After powering off a power 
supply, wait 60 seconds before turning it back on.