LEDs
M40 Internet Router Hardware Guide
192
LEDs
The LEDs described in the following sections indicate the basic status of hardware 
components:
LEDs on the Craft Interface
The craft interface hosts LEDs and an LCD that provide status and troubleshooting 
information at a glance. It is located on the front of the chassis below the FPC card cage (see 
Figure 1). The LEDs on the craft interface include the following:
„ Alarm—The circular red alarm LED at the left of the craft interface indicates a critical 
condition that can result in a system shutdown. The triangular yellow alarm next to it 
indicates a less severe condition that requires monitoring or maintenance. Both alarms 
can occur simultaneously. When an alarm LED is lit, the LCD describes the cause of the 
alarm. For more information about the alarm LEDs, see “Alarm Relay Contacts, LEDs, 
and Cutoff Button” on page 18.
 For more information about the causes of alarms, see 
“Hardware and Interface Alarm Messages” on page 192.
„ FPC—For each of the eight FPC slots in the router, there are two LEDs and an offline 
button located on the craft interface directly below the slot. The green LED labeled 
OK
 
and red LED labeled 
FAIL
 indicate FPC status. For more information, see “FPC LEDs and 
„ Routing Engine— LEDs at the right side of the craft interface indicate the status of the 
Routing Engine—a green one labeled 
OK
 and a red one labeled 
FAIL
. For more 
LEDs on Hardware Components
LEDs on the faceplates of many hardware components report component status:
„ PIC—Most PICs have an LED labeled 
STATUS
 on the PIC faceplate. Some PICs have 
additional LEDs, often one per port. The meaning of the LED states differs for various 
PICs. For more information, see the M20 and M40 Internet Routers PIC Guide.
„ Power supply—A red 
FAIL
 LED and a green 
OK
 LED are located on each power supply 
faceplate and indicate the status of the power supply. See “Power Supply LEDs” on 
page 22.
„ SCB—Four LEDs on the faceplate of the SCB indicate its status. See “SCB Components” 
Hardware and Interface Alarm Messages
When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on 
the craft interface as appropriate, trips the corresponding alarm relay contact on the craft 
interface, and reports the cause of the alarm in the craft interface LCD. To view a more 
detailed description of the alarm cause, issue the 
show chassis alarms 