Troubleshoot the Power Supplies
195
Chapter 16
Troubleshoot the Power Supplies
When a power supply is functioning correctly, the green LED labeled 
OK
 is lit steadily and the 
red LED labeled 
FAIL
 is not lit.
If the LEDs are in any other states, consult the following sections:
All LEDs on Both Supplies are Off
If all LEDs are off on both power supply faceplates, either someone has switched off power to 
the router or the system temperature has exceeded the acceptable maximum. In the latter 
case, the Routing Engine shuts down both power supplies. There is no power to the router, so 
the alarm LEDs on the craft interface are not lit.
Excessive system temperature is almost always caused by excessive environmental 
temperature. Correct the environmental temperature before powering the router on again.
All LEDs on One Supply are Off or LED States are not Correct
If either of the following conditions apply, perform the diagnostic procedure that follows:
„ The LEDs on one power supply are all off, but the LEDs on the other supply indicate that 
it is functioning properly.
„ The LED states on one or both supplies indicate a problem: the green LED labeled 
OK
 is 
not lit and the red LED labeled 
FAIL
 is lit.