Troubleshoot the Fan Tray and Impeller Assemblies
M40 Internet Router Hardware Guide
198
Troubleshoot the Fan Tray and Impeller Assemblies
To troubleshoot the fan tray and impeller assemblies, follow these guidelines:
„ If the red alarm LED on the craft interface lights, check the LCD on the craft interface for 
the source of the problem. The display reports the number of alarm conditions and the 
source of each alarm. For a list of messages, see “Hardware and Interface Alarm 
Messages” on page 192.
„ Issue the following CLI command for more information about the source of an alarm 
condition:
user@host> show chassis alarms
„ Issue the following command to check the status of the fans and impellers:
„ To check the status of the impellers and fans, issue the 
show chassis environment
 
command. The output refers to the 
Top 
and
 Bottom
 impellers and to the individual fans 
in the fan tray as the 
Rear Left Fan
Rear Center Fan
, and 
Rear Right Fan
:
user@host> show chassis environment
Class Item                   Status     Measurement
Fans  Top Impeller           OK         Spinning at normal speed
      Bottom Impeller        OK         Spinning at normal speed
      Rear Left Fan          OK         Spinning at normal speed
      Rear Center Fan        OK         Spinning at normal speed
      Rear Right Fan         OK         Spinning at normal speed
For further description of the output from the command, see the JUNOS Internet 
Software Operational Mode Command Reference: Protocols, Class of Service, Chassis, and 
Management
.
„ Place your hand near the exhaust at the upper rear of the chassis to determine whether 
the impellers and fans are expelling air.
„ If both power supplies have failed, the system temperature might have exceeded the 
threshold, causing the system to shut down. See “All LEDs on Both Supplies are Off” on 
page 205.
„ If the LCD on the craft interface reports failure of only one impeller and the other 
impellers are functioning normally, the impeller is probably faulty and needs to be 
replaced. For replacement instructions, see “Maintain and Replace Cooling System 
Components” on page 153.
 For instructions about returning a faulty component to 
Juniper Networks, see “Return the Router or Its Components” on page 215.
„ If one of the fan assemblies fails, look at the fan to determine whether the blades of the 
fan are rotating. Individual blades are not distinguishable when the fan is rotating at 
normal speeds.