Troubleshoot the Packet Forwarding Engine Components
201
Chapter 18
Troubleshoot the Packet Forwarding Engine Components
This chapter discusses the following topics related to troubleshooting components of the 
Packet Forwarding Engine:
Troubleshoot FPCs
As soon as an FPC is seated on an operating router, the Routing Engine downloads the FPC 
software to it. The FPC then runs diagnostics and enables the PICs that it houses. During this 
time, the green FPC LED labeled 
OK
 on the craft interface is blinking. When the FPC is online 
and functioning normally, the 
OK
 LED lights steadily.
To troubleshoot FPCs, follow these guidelines:
„ If the red FPC LED labeled 
FAIL
 lights steadily, make sure the FPC is properly seated in 
the backplane—use a Phillips screwdriver to check that the screws at the top and bottom 
of the card carrier are tight. 
„ Issue the CLI 
show chassis fpc
 command to check the status of installed FPCs. As shown 
in the sample output, the value 
Online
 in the column labeled 
State
 indicates that the FPC 
is functioning normally:
user@host> show chassis fpc
Temp  CPU Utilization (%)   Memory    Utilization (%)
Slot State 
(C)  Total  Interrupt      DRAM (MB) Heap     Buffer
  0  Online 
28      1          0         8         9         15
  1  Online 
27      1          0         8         9         15
  2  Online 
29      1          0         8        12         14
  3  Empty           
  4  Empty           
  5  Online 
25      0          0         8         8         14
  6  Online 
29      1          0         8         9         14
  7  Online 
26      1          0         8         8         13