Juniper CBL-M40-PWR-AU ユーザーズマニュアル

ページ / 268
Craft Interface
M40 Internet Router Hardware Guide
18
FPC LEDs and Offline Button
Each of the eight FPC slots in the router has two LEDs and an offline button located directly 
below it on the craft interface, as shown in Figure 7. The green LED labeled 
OK
 and red LED 
labeled 
FAIL
 indicate FPC status, as described in Table 5
The offline button, labeled with the FPC slot number (for example, 
4
), prepares the FPC for 
removal from the router when pressed. Press and hold the button for about 5 seconds, until 
the 
FAIL
 LED lights.
Table 5:  States for FPC LEDs
Alarm Relay Contacts, LEDs, and Cutoff Button
The area labeled 
ALARM
 at the left side of the craft interface contains two alarm LEDs and 
relay contacts, and the alarm cutoff button (see Figure 7). The circular LED, labeled 
RED ALARM
, lights to indicate a critical condition that can result in a system shutdown. The 
triangular LED, labeled 
YELLOW ALARM
, lights to indicate a less severe condition that requires 
monitoring or maintenance. Both LEDs can be lit simultaneously. The LCD on the craft 
interface reports the cause of the alarm.
To the left of the LEDs are the corresponding relay contacts for connecting the router to 
external alarm-reporting devices. A system condition that causes the red or yellow alarm LED 
to light on the craft interface also activates the corresponding alarm relay contact. For 
instructions for attaching a device to the alarm relay contacts, see “Connect to an External 
Alarm-Reporting Device” on page 121.
To deactivate red and yellow alarms, press the button labeled 
ALARM CUTOFF
, which is located 
to the right of the alarm LEDs. Deactivating an alarm turns off both LEDs and deactivates the 
device attached to the corresponding alarm relay contact. However, the LCD continues to 
report the alarm message until you clear the condition that caused the alarm.
 Label
Shape
 Color
State
Description
OK
Green
On steadily
FPC is functioning normally.
Blinking
FPC is starting up.
FAIL
Red
On steadily
FPC has failed or is offline.