CIS-201 RS-232 Protocol
Overview
Transfer Format
Transfer Rate
9600bps
Character Length
8 bits
Parity Check
None
Start Bit
1
Stop Bit
1
ID Number
CIS-201 ID Number = Selectable 1 through 15
(ID number 0 is reserved for the CIS-200).
Channel Number
Control-S / Infrared Channel Assignments:
Channel 1 = 01H
Channel 2 = 02H
Channel 3 = 04H
Channel 4 = 08H
Note: Multiple channels may be sent by ‘OR-ing’ channel numbers,.i.e,
00H = N/A
04H = Ch 3
08H = Ch 4
0CH = Ch’s 3,4
01H = Ch 1
05H = Ch’s 1,3
09H = Ch’s 1,4
0DH = Ch’s 1,3,4
02H = Ch 2
06H = Ch’s 2,3
0AH = Ch’s 2,4
0EH = Ch’s 2,3,4
03H = Ch’s 1,2
07H = Ch’s 1,2,3
0BH = Ch’s 1,2,4
0FH = All Channels
Send Strings:
Control-S Send Strings
Send Control-S Data
Send Control-S Data Continuous
Stop ALL Data