Page 5
Figure 1: RH-25 baseband block diagram
Functional Description
Modes of Operation
The RH-25 baseband engine has five different operating modes:
1 No supply
2 Acting  Dead
3 Active
4 Sleep
5 Charging
No Supply Mode
In NO_SUPPLY mode, the phone has no supply voltage. This mode is due to the discon-
nection of main battery or low battery voltage level.  The phone will exit from 
NO_SUPPLY mode when a sufficient battery voltage level is detected. The battery voltage 
 
UEM
IHF
UPP 
Combo Memory
 64Mbit 
Flash/4Mbit SRAM
TACO RF Module 
Audio Amp
 
Battery 
Keyboard
(UI Module)
IrDa 
1.8V 
LCD
 
Passive color STN 
 color display 
System connector
Tomahawk
 
DC 
jack 
Charger 
Accessory 
Regulator 
2.8V 70mA 
IHF
Led Driver 
Keyboard & 
display 
illumination 
Vibra
 
Ext Audio 
Connector