Troubleshooting - Baseband
CCS Technical Documentation
Page 8
 ©
2003 Nokia Corporation         Confidential
Issue 1 11/2003
Power up with PWR key
When the Power on key is pressed, the UEM enters the power up sequence. Pressing the 
power key causes the PWRONX pin on the UEM to be grounded. The UEM PWRONX sig-
nal is not part of the keypad matrix. The power key is only connected to the UEM. This 
means that when pressing the power key, an interrupt is generated to the UPP that starts 
the MCU. The MCU then reads the UEM interrupt register and notices that it is a 
PWRONX interrupt. The MCU now reads the status of the PWRONX signal using the UEM 
control bus, CBUS. If the PWRONX signal stays low for a certain time, the MCU accepts 
this as a valid power on state and continues with the SW initialization of the baseband. 
If the power on key does not indicate a valid power on situation the MCU powers off the 
baseband.
Power up when charger is connected
In order to be able to detect and start charging in the case where the main battery is 
fully discharged (empty) and hence UEM has no supply (NO_SUPPLY or BACKUP mode of 
UEM), charging is controlled by START-UP CHARGING circuitry.
Whenever VBAT level is detected to be below master reset threshold (VMSTR-), charging 
starts and is controlled by START_UP charge circuitry. Connecting a charger forces 
VCHAR input to rise above the charger detection threshold, VCHDET+, and by detection 
charging is started. UEM generates 100mA constant output current from the connected 
charger's output voltage. As battery charges, its voltage rises and when VBAT voltage 
level is detected to be higher than the master reset threshold limit (VMSTR+), START_UP 
charge is terminated.