Zippy Technology MRG-5800V4V ユーザーズマニュアル

ページ / 43
PAGE  1
ZIPPY EMC LAB
conduction test
EUT:
Manuf:
Op Cond:
Operator:
Test Spec:
Comment:
MRG-5800V4V SPS
ZIPPY TECH CO..LTD
FULL LOAD
EDMENT
EN 55022-- Class B 
Load Condition( 50  21 0.8  19  3.5 ) 
L220V
Scan Settings
Frequencies
Receiver Settings
Start
Stop
Step
IF BW
Detector
M-Time
Atten
Preamp
OpRge
(3  Ranges)
150kHz
500kHz
2kHz
10kHz
QP+AV
1msec
Auto
OFF
60dB
500kHz
5MHz
20kHz
10kHz
QP+AV
1msec
Auto
OFF
60dB
5MHz
30MHz
50kHz
10kHz
QP+AV
1msec
Auto
OFF
60dB
Transducer
No.
Start
Stop
Name
1
9kHz
30MHz
CEB
Meas Time:
Peaks:
Acc Margin:
Prescan Measurement:
Detectors:
X QP / + AV
see scan settings
8
25 dB
dBµV
100
0
10
20
30
40
50
60
70
80
90
MHz
30.0
0.15  
1.0
10.0
EN_QP_B
EN_AV_B