Panasonic cu-e18gfe-2 ユーザーズマニュアル

ページ / 42
5
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6
°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Turbo Fan
Propeller Fan
Material
ASG
PP
Motor Type
Transistor (8-pole)
Induction (6-pole)
Input Power
W
66.0 - 74.1
Output Power
W
48
25
Fan Speed
QLo (Cool/Heat)
rpm
 360 / 360
Lo (Cool/Heat)
rpm
 410 / 410
Me (Cool/Heat)
rpm
510 / 520
Hi (Cool/Heat)
rpm
620 / 630
745 - 790 / -
SHi (Cool/Heat)
rpm
660 / 670
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 22 x 19
2 x 24 x 17
Size (W x H x L)
mm
510 x 396 x 24
36.4 x 504 x 713
684
Air Filter
Material
PET
Type
Honeycomb
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 240
Hz
50
Input Power
W
Cooling; 570 (175 ~ 780)
Heating; 865 (165 ~ 1360)
Starting Current
A
4.20
Running Current
A
Cooling; 2.75 - 2.65
Heating; 4.20 - 3.90
Maximum current
A
6.15
Power Factor
%
Cooling; 94 - 90
Heating; 94 - 92
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT