10.8.32  SET MAX ADDRESS EXT (37h) 
 
COMMAND CODE 
0 0 1 1 0 1 1 1
 
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
 
drive no. 
no change 
LBA 
Low 
Current 
Previous 
Max LBA(7:0) 
Max LBA(31:24) 
HOB=0
HOB=1
no change 
no change 
LBA 
Mid 
Current 
Previous 
Max LBA(15:8) 
Max LBA(39:32) 
HOB=0
HOB=1
no change 
no change 
LBA 
High 
Current 
Previous 
Max LBA(23:16) 
Max LBA(47:40) 
HOB=0
HOB=1
no change 
no change 
SC Current 
Previous 
00
H
 / 01
 H 
   
reserved 
HOB=0
HOB=1
no change 
no change 
FT Current 
Previous 
reserved 
reserved 
HOB=0
HOB=1
no change 
no change 
 
This command specifies the the maximum address in a range of actual drive capacity. If the address exceeding 
the set value is accessed , “ ABORT ERROR “ error will be reported. This set value affects the values of WORD 
60, 61, 100-103 of IDENTIFY DEVICE command.   
  This command shall be immediately preceded by Read Native Max Address EXT command. Otherwise, it will 
be terminated with “ ABORT ERROR ” . 
  If this command is issued twice with a volatile bit set to 1 after power-up or hardware reset,    “ID Not Found 
error” will be reported. 
  If a host protected area has been established by a SET MAX ADDRESS command, this command will be 
terminated with “ ABORT ERROR ” . 
Volatile bit ( SC register bit 0 ) :   
  If this command is issued with a volatile bit set to 1, the set value of this command is valid after power-up or 
hardware reset. 
  If this command is issued with a volatile bit cleared to 0, the set value of this command shall be cleared after 
hard reset or power-on and the maximam value shall be the last value with a volatile bit set to 1.   
     
10.8.33  Read Native Max Address      (F8h) 
 
COMMAND CODE 
1 1 1 1 1 0 0 0
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
DRIVE No. 
no change 
CY 
 
maximum cylinder number 
HD 
 
maximum head number 
SN 
 
maximum sector number 
LBA  
maximum 
LBA 
 
This command sets the maximum address in CY, HD, SN register. If LBA ( DRV / HD register bit6 ) is set to 1, 
the maximum address shall be LBA value. 
 
If the 48-bit native max address is greater than 268,435,455, the Read Native Max Address command shall 
return a maximum value of 268,435,454.