4.44 AT+CSCS Set TE character set
Test command
AT+CSCS=?
Response
+CSCS: (list of supported <chset>s)
OK
OK
Read command
AT+CSCS?
Response
+CSCS: <chset>
OK
Write command
AT+CSCS=[<chset>]
Response
Write command informs TA which character set <chset> is used by the TE.
TA is then able to convert character strings correctly between TE and ME
character sets.
OK
TA is then able to convert character strings correctly between TE and ME
character sets.
OK
Parameters
<chset>:
"GSM" GSM default alphabet (GSM 03.38 subclause 6.2.1);
"GSM" GSM default alphabet (GSM 03.38 subclause 6.2.1);
Note: This setting may cause software flow control problems since
the codes used to stop and resume data flow (XOFF = decimal 19,
(XON = decimal 17) are interpreted as normal characters.
the codes used to stop and resume data flow (XOFF = decimal 19,
(XON = decimal 17) are interpreted as normal characters.
"UCS2" 16-bit universal multiple-octet coded character set (ISO/IEC10646
[32]); UCS2 character strings are converted to hexadecimal num-
bers from 0000 to FFFF; e.g. "004100620063" equals three 16-bit
characters with decimal values 65, 98 and 99, $(AT R97)$
bers from 0000 to FFFF; e.g. "004100620063" equals three 16-bit
characters with decimal values 65, 98 and 99, $(AT R97)$
Reference
GSM 07.07
Note
· Also see chapter 1.5 (“Supported character sets”).
· When TA-TE interface is set to 8-bit operation and used TE alphabet is
7-bit, the highest bit will be set to zero.