8.4  AT^SACM  Advice of charge and query of ACM and ACMmax 
Test command 
AT^SACM=? 
Response 
^SACM: (list of supported <n>s) OK 
Parameter 
See write command 
 
Execute command 
AT^SACM 
The execute command can be used to query the current mode of the Advice of 
Charge supplementary service, the SIM values of the accumulated call meter 
(ACM) and accumulated call meter maximum (ACMmax). 
 
Response  
^SACM: <n>,<acm>,<acm_max> OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
 
Parameter 
<n> See 
write 
command 
<acm> 
ACM, string type; three bytes of the current ACM value in hexadeci-
mal format (e.g. “00001E” indicates decimal value 30) 000000–
FFFFFF 
<acm_max>  ACMmax, string type; three bytes of the max. ACM value in hexade-
cimal format (e.g. “00001E” indicates decimal value 30) 000000 dis-
able ACMmax feature 000001-FFFFFF 
<ccm> 
string type; three bytes of the current CCM value in hexadecimal for-
mat (e.g. “00001E” indicates decimal value 30); bytes are coded in 
the same way as ACMmax value in the SIM 000000-FFFFFF 
 
Write command 
AT^SACM=<n> 
The write command enables or disables the presentation of unsolicited result to 
report the call charges. 
 
Response 
OK or if error is related to ME functionality: +CME ERROR: <err> 
 
Parameter 
<n>
 
suppress unsolicited result code 
 
display unsolicited result code 
 
When you power down or reset the ME with AT+CFUN=1,1 the URC 
presentation mode will be reset to its default. To benefit from the 
URC it is recommended to have the setting included in the user pro-
file saved with AT&W, or to select <n>=1 every time you reboot the 
ME. 
 
Unsolicited result code 
When activated, an unsolicited result code is sent when the CCM value changes, 
but not more often than every 10 seconds 
+CCCM: <ccm> 
 
Reference 
Siemens 
Note 
See also GSM07.07: AT+CACM, AT+CAMM, AT+CAOC