2.38  AT&W  Store current configuration to user defined profile  
Execute command 
AT&W[<n>] 
TA stores the current settings to a user defined profile in the non-volatile memory. 
 
Response 
OK or if error is related to ME functionality: ERROR / +CME ERROR: <err> 
 
Parameter 
<n> 
0  number of profile 
 
Reference 
V.25ter 
Note 
The user defined profile will be loaded automatically after PowerUp. Use ATZ to 
restore user profile and AT&F to restore factory settings. Until the first use of 
AT&W, ATZ works as AT&F. See Chapter 2.32 for details on ATZ and Chapter 
2.35 for AT&F. 
 
List of settings stored to user defined profile: 
·  ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR, 
AT+CMEE, AT^SMGO, AT+CSMS,  AT^SACM, ^SCKS, AT+CREG, AT+CLIP, 
AT+COPS. 
AT&C, AT&D, AT&S, ATS0, ATS3, ATS4, ATS5, ATS6, ATS7, ATS8, ATS10, 
ATS18, AT+FCLASS, AT+CBST, AT+CRLP, AT+CR. 
 
User defined profiles in multiplex mode: 
·  On each multiplexer channel you can save an individual profile. 
·  List of settings stored to profile on multiplexer channel 1:  
ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR, 
AT+CMEE, AT^SMGO, AT+CSMS,  AT^SACM, ^SCKS, AT+CREG, AT+CLIP, 
AT+COPS. 
AT&C, AT&D, AT&S, ATS0, ATS3, ATS4, ATS5, ATS6, ATS7, ATS8, ATS10, 
ATS18, AT+FCLASS, AT+CBST, AT+CRLP, AT+CR. 
·  List of settings stored to profile on multiplexer channels 2 and 3:  
ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR, 
AT+CMEE, AT^SMGO, AT+CSMS,  AT^SACM, ^SCKS, AT+CREG, AT+CLIP, 
AT+COPS. (Parameters for data call are not relevant on channels 2 and 3.)