Siemens MC35 ユーザーズマニュアル

ページ / 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 63 of 256 
15.07.2002 
4  AT Commands originating from GSM 07.07 
These AT Commands are according to ETSI (European Telecommunications Standards Institute) 
GSM 07.07 document. 
 
4.1  AT+CACM  Accumulated call meter (ACM) reset or query 
Test command 
AT+CACM=? 
Response 
OK 
Parameter 
 
Read command 
AT+CACM? 
Response 
TA returns the current ACM value. 
+CACM: <acm> OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
 
Parameter 
<acm> 
string type; three bytes of the current ACM value in hexadecimal for-
mat (e.g. “00001E” indicates decimal value 30) 000000 – FFFFFF 
 
Write command 
AT+CACM= 
[<passwd>] 
Parameter 
<passwd> string type: 
 
SIM  PIN2 
 
Response 
TA resets the Advice of Charge related to the accumulated call meter (ACM) 
value in SIM file EF(ACM). ACM contains the total number of home units both 
for the current and preceding calls. 
 
OK 
 
If error is related to ME functionality: 
+CME ERROR: <err> 
 
Reference 
GSM 07.07