4.3  AT+CAMM  Accumulated call meter maximum (ACMmax) set or query 
Test command 
AT+CAMM=? 
Response 
OK 
Parameter 
 
Read command 
AT+CAMM? 
Response 
TA returns the current ACMmax value. 
+CAMM: <acmmax> OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Parameter 
See write command 
 
Write command 
AT+CAMM= 
[<acmax>[,<passwd>]] 
Response 
TA sets the Advice of Charge related to the accumulated call meter maxi-
mum value in SIM file EF (ACMmax). ACMmax contains the maximum 
number of home units allowed to be consumed by the subscriber.  
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
 
Parameter 
<acmmax>  string type; three bytes of the max. ACM value in hexadeci-
mal format (e.g. “00001E” indicates decimal value 30) 000000 
disable ACMmax feature 000001-FFFFFF 
<passwd> string 
type 
 SIM 
 
PIN2 
 
Reference 
GSM 07.07 