Electrolux 534076 ユーザーズマニュアル

ページ / 40
ENGLI
S
H
17
E6.1
Plumbing circuits
Cold water connection ISO 228/1 DN 20 (G3/4”).
4-15°C 39°F-59°F 150 - 700 kPa (21.7 - 101.5 PSI / 1.5 - 7 bar) at 0.07 gal/sec (0.3 l/sec).
Hot water connection ISO 228/1 DN 20 (G3/4").
150 - 700 kPa (21.7 - 101.5 PSI / 1.5 - 7 bar) at 0.07 gal/sec (0.3 l/sec).
The supply water temperature is related to the machine setup.
MACHINES WITH BOILER:
MACHINES WITHOUT BOILER:
If the water pressure is less than 150 kPa (21.7 PSI - 1.5 
bar) a booster pump must be installed ahead of the 
machine. 
This pump can be requested as an optional, and if 
ordered together with the machine it is supplied already 
installed on the water connection fitting. If the pressure 
at one of the unions exceeds 700 kPa (101.5 PSI - 7bar), 
a pressure reducing valve must be installed on the inlet 
piping. Connection pipes with anti-return protection and 
check valve and stop cock are available as optional 
accessories.
If the water hardness exceeds 14°fH/8°dH/10°cH, install 
a softener filter on the dishwasher inlet connection pip-
ing to ensure efficient machine operation.
Connect the appliance water supply to the mains, fitting 
a cut-off cock, a filter and a pressure gauge between the 
appliance and the mains.
.
Figure 8   Water connection
MA
CHINES
 WITH 
BOILER
RISE 40°F/ 22°C
Inlet water temperature min. 140°F/ 60°C
for RINSE and WASH CIRCUIT
RISE 70°F/ 39°C
Inlet water temperature min. 110°F/ 43.3°C
for RINSE and WASH CIRCUIT
RISE 100°F/ 56°C
Inlet water temperature min. 80°F/ 26.6°C
for RINSE and WASH CIRCUIT
MA
CHINES
 WITHOUT 
BOILER
Inlet water temperature min. 194°F/ 90°C
for RINSE CIRCUIT
Inlet water temperature 80-140°F/ 27-60°C
for WASH TANK
Inlet water temperature 39-59°F/ 4-15°C
for PREWASH TANK
IMPORTANT!
Connect the prewash zone to the cold 
water inlet and connect the rinse zone to 
the hot water inlet
!