Electrolux 506030 ユーザーズマニュアル

ページ / 20
ENGLISH
11
A fused disconnect switch or a main circuit breaker 
(customer furnished) MUST be installed in the 
electric supply line for the appliance. It is recom-
mended that this switch/circuit breaker have 
lockout/tagout capability. Before making any electri-
cal connections to this appliance, check that the 
power supply is adequate for the voltage, amperage, 
and phase requirements on the rating plate.
RATING PLATE
The rating plate contains identification and technical 
data and is located on the right-hand side panel of the 
appliance (Figure 7).
Figure 7
C1
WATER CONNECTION
Position the potwasher and level the appliance by 
adjusting the appropriate bullet feet (Figure 7).
Connect the appliance water supply pipe “A” 
(Figure 4/Figure 5/Figure 6) 
(keeping 
with 
local 
plumbing codes) to the incoming water supply. Install 
a shutoff valve, Y-Strainer and a pressure gauge 
between the appliance and the incoming water sup-
ply of the unit (Figure 8).
Figure 8
Check that the 
dynamic 
water supply 
pressure
measures 
between 7.25 - 101 psi/50 - 700kPa
 while 
potwasher tank or boiler is filling with water. 
If the pressure is too high, install a suitable pressure 
regulator on the incoming water supply to the unit.
On models with free-fall drainage:
connect the waste outlet pipe “C” (Figure 4/Figure 5/ Figure 6) to the main drain pipe, using a trap, or place 
the outlet pipe over an “S” trap set into the floor. 
On models with drain pump: 
position the outlet pipe at a height anywhere between 29 
1/2” to 39 3/8”/750 and 1000 mm from the floor.
Check that about 1 gallon/4 litres of water flow out of the 
outlet pipe during the rinse cycle.
Make sure drain hose does not kink, pinch or twist, 
resulting in a water flow restriction.
C2
ELECTRICAL CONNECTION
Figure 9
The installation of this unit must conform to local 
codes or, in the absence of local codes, to all Natio-
nal Codes governing plumbing, sanitation, safety 
and good trade practices.
Check the over rating plate before making any 
electric supply connections. Electric supply connec-
tions must agree with data on the unit rating plate.
The earth wire at the terminal end must be 
3/4”/20 mm (max.) longer than the phase wires.
The appliance requires a ground connection to the 
unit ground screw located at the rear of the unit 
marked “Q” (Figure 
4/Figure 5/Figure 6)  in  the 
manual and marked with the symbol “
“ on the unit. 
C
INSTALLATION AND START-UP INSTRUCTIONS
Model PW1M
PNC 9CGX 506029 05   Ser.N .123000001
AC 400V 3N                50Hz
Power Boiler              10500w
Power Tank               12000w
Power Max                22000w
       Made in EU
Model PW1M
PNC    9CGX506029 05
Ser.N .123000001
!
CAUTION
 
THE ELECTRICAL CONNECTIONS MUST 
MEET ALL NATIONAL AND ELECTRICAL 
CODE REQUIREMENTS.
AC
  208....
!