STATUS INDICATORS
When the following indicators light up or blink on the operation panel or the following 
alphanumeric codes appear in the display, solve the problem immediately referring 
to both the table below and the relevant page.
Be sure to use only genuine SHARP parts and supplies.
Indication
Cause and remedy
Page
Drum replacement 
required indicator
Steadily 
lit
Replacement of drum cartridge will be needed
soon. Prepare a new cartridge.
71
Blinking Drum cartridge must be replaced. Replace it with a new one.
58
TD cartridge 
replacement 
required indicator
Steadily 
lit
Replacement of TD cartridge will be needed 
soon. Prepare a new cartridge.
71
Blinking TD cartridge must be replaced. Replace it with a new one.
57
Misfeed indicator
Blinking
A misfeed has occurred. Remove the misfed paper 
referring to the description of "MISFEED REMOVAL".
63
SPF misfeed 
indicator
Steadily 
lit
When the document feeder cover is open.
Blinking
An original misfeed has occurred in the SPF. 
Remove the misfed originals referring to the 
description of "E: Misfeed in the SPF".
67
Power save indicator is 
steadily lit.
The unit is in the preheat mode. Press any key to 
cancel the preheat mode.
54
The unit is in the auto power shut-off mode. 
Press the start (
) key to cancel the auto power 
shut-off mode.
54
The paper tray indicator is 
blinking.
The paper tray is not pushed in correctly, or there 
is no paper in the tray. Push the tray all the way 
in or load paper in the tray.
"CH" is blinking in the display.
The TD cartridge is not installed. Check if the 
cartridge is installed.
57
"CH" is steadily lit in the 
display.
Side cover is open. Close the side cover securely 
by pressing the round projections near the side 
cover open button.
"OP" is blinking in the display.
This appears if it is detected that the OC cover is 
open when copying is started. Completely close 
the OC cover, or press the start (
) key again.
Depending on the color and the density of the 
original, "OP" blinking may appear even when 
the OC cover is closed. In such a case, press the 
start key again to make a copy.
"P" is blinking in the display.
The paper tray or multi-bypass tray is empty. 
Load paper.
15, 17
A misfeed has occurred in the paper tray or 
multi-bypass tray. Remove the misfed paper.
63
A letter and a number appear 
alternately.
The scan head locking switch is locked. Unlock 
the scan head locking switch.
9
A letter and a number appear 
alternately.
The unit will not function. Turn the power switch 
off, remove the power cord from the outlet, and 
contact our Technical Assistance Department at 
1-(630)378-3590 in the USA.
08-Trouble.fm  62 ページ  2007年4月18日 水曜日 午後1時12分