Zebra 50-12500-066 ユーザーズマニュアル

ページ / 450
SYMBOLOGIES 11 - 33
Code 39 Buffering - Scan & Store (continued)
This feature affects Code 39 only. If selecting Buffer Code 39, we recommend configuring the linear imager 
scanner to decode Code 39 symbology only.
While there is  data  in  the transmission buffer,  you cannot select Do Not Buffer Code 39. The buffer holds 
200 bytes of information.
To disable Code 39 buffering when there is data in the transmission buffer, first force the buffer transmission 
(see 
) or clear the buffer.
Buffer Data
To buffer data, enable Code 39 buffering and scan a Code 39 symbol with a space immediately following the 
start pattern.
Unless the data overflows the transmission buffer, the linear imager scanner issues a low/high beep to 
indicate successful decode and buffering. (For overflow conditions, see 
The linear imager scanner adds the decoded data excluding the leading space to the transmission buffer.
No transmission occurs.
Clear Transmission Buffer
To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a 
dash (minus), and a stop character.
The linear imager scanner issues a short high/low/high beep.
The linear imager scanner erases the transmission buffer.
No transmission occurs.
Buffer Code 39 (Enable)
(01h)
*
Do Not Buffer Code 39 (Disable)
(00h)
Clear Buffer
NOTE
The Clear Buffer contains only the dash (minus) character. In order to scan this command, set Code 39 
lengths to include length 1.