Zebra 50-12500-066 ユーザーズマニュアル

ページ / 450
SYMBOLOGIES 11 - 65
Redundancy Level
Parameter # 4Eh
The linear imager scanner offers four levels of decode redundancy. Select higher redundancy levels for 
decreasing levels of bar code quality. As redundancy levels increase, the linear imager scanner’s 
aggressiveness decreases.
Select the redundancy level appropriate for the bar code quality.
Redundancy Level 1
The following code types must be successfully read twice before being decoded:
Redundancy Level 2
The following code types must be successfully read twice before being decoded:
Redundancy Level 3
Code types other than the following must be successfully read twice before being decoded. The following 
codes must be read three times:
Table 11-2    
Redundancy Level 1 Codes
Code Type
Code Length
Codabar
8 characters or less
MSI
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Table 11-3    
Redundancy Level 2 Codes
Code Type
Code Length
All
All
Table 11-4    
Redundancy Level 3 Codes
Code Type
Code Length
MSI 
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Codabar
8 characters or less