Zebra 50-12500-066 ユーザーズマニュアル
RADIO COMMUNICATIONS 4 - 17
Out of Range Indicator
An out of range indicator can be set by scanning
and
extending the time using the
For example, with Beep on Reconnect Attempt disabled while the linear imager scanner loses radio connection
when it is taken out of range, the linear imager scanner attempts to reconnect silently during the time interval
set by scanning a Reconnect Attempt Interval.
when it is taken out of range, the linear imager scanner attempts to reconnect silently during the time interval
set by scanning a Reconnect Attempt Interval.
When Beep on Reconnect Attempt is enabled, the linear imager scanner emits 5 high beeps every 5 seconds
while the reconnection attempt is in progress. If the Reconnect Attempt Interval is adjusted to a longer period
of time, such as 30 minutes, the linear imager scanner emits 5 high beeps every 5 seconds for 30 minutes
providing an out of range indicator.
while the reconnection attempt is in progress. If the Reconnect Attempt Interval is adjusted to a longer period
of time, such as 30 minutes, the linear imager scanner emits 5 high beeps every 5 seconds for 30 minutes
providing an out of range indicator.
Beep on Insertion
Parameter # F0 20h
When a linear imager scanner is inserted into a cradle and detects power, it emits a short low beep. This
feature is enabled by default.
feature is enabled by default.
To enable or disable beeping on insertion, scan the appropriate bar code below.
*
Enable Beep on Insertion
(00h)
Disable Beep on Insertion
(01h)