Epson RX-8581JE ユーザーズマニュアル

ページ / 32
RX
    
-
    
8581
        
SA
    
/
    
JE
    
/
    
NB
 
 
 
Page - 22 
MQ372-02
 
 
8.6.3. Starting and stopping I
2
C bus communications 
 
SCL 
START 
condition 
SDA 
0.95
  
s ( Max. ) 
Repeated START(RESTART) 
condition 
STOP 
condition 
 
[ S ] 
 
 
[ Sr ]
 
[ P ]
 
 
1) START condition, repeated START condition, and STOP condition 
 
(1) START condition   
     
  The SDA level changes from high to low while SCL is at high level.   
 
(2) STOP condition 
 This condition regulates how communications on the I2C-BUS are terminated.   
  The SDA level changes from low to high while SCL is at high level.   
 
(3) Repeated START condition (RESTART condition) 
 In some cases, the START condition occurs between a previous START condition and the next 
STOP condition, in which case the second START condition is distinguished as a RESTART 
condition. Since the required status is the same as for the START condition, the SDA level changes 
from high to low while SCL is at high level.   
 
2) Caution points   
 
1)  The master device always controls the START, RESTART, and STOP conditions for communications.   
 
2)  The master device does not impose any restrictions on the timing by which STOP conditions affect 
transmissions, so communications can be forcibly stopped at any time while in progress. (However, 
this is only when this RTC module is in receiver mode (data reception mode = SDA released). 
 
3)  When communicating with this RTC module, the series of operations from transmitting the START 
condition to transmitting the STOP condition should occur within 0.95 seconds. (A RESTART 
condition may be sent between a START condition and STOP condition, but even in such cases the 
series of operations from transmitting the START condition to transmitting the STOP condition should 
still occur within 0.95 seconds.) 
 
 
 
If this series of operations requires 0.95 seconds or longer, the I
2
C bus interface will be automatically 
cleared and set to standby mode by this RTC module's bus timeout function. Note with caution that 
both write and read operations are invalid for communications that occur during or after this auto 
clearing operation. (When the read operation is invalid, all data that is read has a value of "1"). 
 
Restarting of communications begins with transfer of the START condition again 
 
4)  When communicating with this RTC module, wait at least 1.3 µs (see the tBUF rule) between 
transferring a STOP condition (to stop communications) and transferring the next START condition (to 
start the next round of communications).   
 
 
SCL 
SDA 
61
  µµµµ
s (Min.) 
STOP 
condition 
START 
condition 
 
[ P ] 
 